The Yokogawa MUD*A (commonly referenced as the MUD*A or MUD-A) operates as a general-purpose, rack-mounted terminal board within Yokogawa’s industrial automation platforms, such as CENTUM distributed control systems (DCS). It serves as a centralized mechanical and electrical marshaling hub natively at the marshalling tier to bridge field instrumentation wiring with high-density I/O modules, maintaining transparent signal propagation parallel to master processor network execution cycles.
| Parameter | Specification |
|---|---|
| Model | MUD*A (e.g., MUD-A*A) |
| Brand | Yokogawa |
| Origin | Japan |
| Weight | 1.3 kg (2.87 lbs) |
| Terminal Density | 32 terminal channels (Dual connection points supporting up to 64 conductors) |
| Termination Connection | Heavy-duty, industrial M4 screw-type terminal blocks |
| Supported Wire Gauges | 24 AWG to 14 AWG ($0.2 \text{ mm}^2$ to $2.0 \text{ mm}^2$) |
| Maximum Current | 3 A continuous per individual terminal |
| Maximum Voltage | 250 V AC/DC operational thresholds |
| Operating Temp | -20°C to +60°C (-4°F to +140°F) |
| Relative Humidity | 10% to 95% RH (non-condensing boundaries) |
| Vibration Resistance | ≤ 0.5 mm P-P (0 to 14 Hz), ≤ 2 $\text{m/s}^2$ (14 to 100 Hz) |
| Mechanical Shock Limits | 5 g or less for an 11 ms pulse duration |
Q: What specific hardware failure states manifest if a terminal screw on the MUD*A is over-torqued beyond specification limits?
A: Over-torquing strips the internal brass threading or deforms the pressure plate assembly. This creates a high-resistance localized connection, causing thermal heat-soak anomalies, intermittent signal attenuation, or complete physical conductor shearing during high-vibration events.
Q: Can field conductors be landed on the MUD*A terminal board while the associated DCS I/O module rack is live and actively scanning loops?
A: Yes, the board is entirely passive. However, technicians must verify that the individual field loops are isolated or unpowered before landing wires to prevent introducing unexpected field shorts or voltage spikes that could damage backend digital acquisition circuits.

Despacho rápido desde nuestro inventario global para reducir el tiempo de inactividad y garantizar operaciones ininterrumpidas.
Todas las piezas provienen de fabricantes acreditados y se someten a exhaustivos controles de calidad.
Amplio stock de repuestos para automatización industrial y piezas descatalogadas, listas para su envío inmediato.
Todos los productos —incluidos los artículos obsoletos— están cubiertos por una garantía de 12 meses y una garantía de devolución de 30 días.
Todos los nombres de productos, marcas comerciales, marcas y logotipos mencionados en este sitio web son propiedad de sus respectivos dueños. Estos nombres y marcas comerciales se utilizan únicamente con fines de identificación y referencia. Somos un proveedor independiente de piezas de repuesto para automatización industrial. No somos un distribuidor autorizado, concesionario o representante de ningún fabricante. Los productos suministrados pueden incluir inventario excedente o artículos sin usar. No reclamamos ninguna afiliación o respaldo por parte de los fabricantes originales.