Oferta
| Color / Pattern |
|
| Power Source |
|
| Controller Design |
|
The Honeywell TK-OAV081, also cataloged as the OAV081 analog output module, operates as a dedicated hardware component for current and voltage signal generation within Honeywell process control systems.
| Parameter | Specification |
|---|---|
| Model | TK-OAV081 |
| Brand | Honeywell |
| Origin | Honeywell process control platforms |
| Weight | 0.5 kg (Shipping weight: 2 kg) |
| Dimensions | Not specified in provided data |
| Operating Temp | Standard industrial ambient range |
| Power Consumption | 6.9 W max |
| Core Function | 8-point analog output (current/voltage) |
| Voltage Output Range | ±10.4 V |
| Current Output Range | 0 to 21 mA |
| Resolution | 320 µV per count (Voltage), 650 nA per count (Current) |
| Accuracy | Better than 0.05% at 25 deg C |
| Isolation | 2550 VDC user-to-system, tested 1 s |
| Protection | Overvoltage protection, short-circuit current limiting |
| Update Rate | 25 ms for all channels |
| Settling Time | <2 ms to 95% final value |
| Connection | TC-TBNH, 20-position terminal block |
The TK-OAV081 supports integration with Honeywell environments utilizing 4-20 mA HART loop protocol, enabling simultaneous analog signal transmission and diagnostic communication. Channel-to-channel isolation ensures that voltage and current outputs remain independent, minimizing interference across the eight channels. Cold junction compensation (CJC) is applied for stability in varying ambient conditions.
Q: Can the TK-OAV081 drive high-resistance loads? A: Yes, voltage outputs can drive >2000 Ω loads, while current outputs support up to 750 Ω.
Q: What is the module’s behavior under short-circuit conditions? A: Outputs are electronically limited to 21 mA or less, preventing damage during open or short circuit events.
Q: How does temperature drift affect accuracy? A: Typical offset drift is 50 µV/deg C (voltage) and 100 nA/deg C (current), with gain drift limited to 25 ppm/deg C (voltage) and 50 ppm/deg C (current).
Mount the module securely in the designated chassis slot.
Connect TC-TBNH 20-position terminal block with proper torque to avoid loose contacts.
Ground shielding at a single point to reduce RFI susceptibility.
Verify load resistance compatibility before energizing outputs.
Maintain clearance for airflow to dissipate 6.9 W maximum heat.

Despacho rápido desde nuestro inventario global para reducir el tiempo de inactividad y garantizar operaciones ininterrumpidas.
Todas las piezas provienen de fabricantes acreditados y se someten a exhaustivos controles de calidad.
Amplio stock de repuestos para automatización industrial y piezas descatalogadas, listas para su envío inmediato.
Todos los productos —incluidos los artículos obsoletos— están cubiertos por una garantía de 12 meses y una garantía de devolución de 30 días.
Todos los nombres de productos, marcas comerciales, marcas y logotipos mencionados en este sitio web son propiedad de sus respectivos dueños. Estos nombres y marcas comerciales se utilizan únicamente con fines de identificación y referencia. Somos un proveedor independiente de piezas de repuesto para automatización industrial. No somos un distribuidor autorizado, concesionario o representante de ningún fabricante. Los productos suministrados pueden incluir inventario excedente o artículos sin usar. No reclamamos ninguna afiliación o respaldo por parte de los fabricantes originales.