Oferta
| Color / Pattern |
|
| Power Source |
|
Configured for digital logic execution and remote serial data telemetry within DCS and PLC architectures, the Honeywell 51308099-100 (51308099-100 Industrial Control Module) provides direct physical/electrical execution. The multi-configuration module bridges field-level sensing arrays and high-current actuator circuits natively at the hardware tier to maintain synchronized process monitoring loops.
| Parameter | Specification |
|---|---|
| Model | 51308099-100 |
| Brand | Honeywell |
| Series | Honeywell DCS / PLC Architecture Component |
| Origin | United States |
| Weight | Standard compact panel-mount module mass |
| Dimensions | Compatible with standard Honeywell marshalling enclosure footprints |
| Nominal Supply Voltage | 24 V DC (Control and PLC interface configurations) |
| Rated Insulation Voltage | Up to 250 V AC maximum |
| Rated Continuous Load Current | 10 A continuous output threshold |
| Maximum Switching Capacity | Up to 15 A peak (variant-dependent boundary) |
| Supported Input Frequency | 40 to 60 Hz (AC control configurations) |
| Digital Input Density | Up to 10 hardware channels |
| Digital Output Density | Up to 6 hardware channels |
| Relay Output Configuration | 2 x Single Pole Double Throw (SPDT) isolated relay contacts |
| Communication Interface | RS-485 serial interface port |
| Supported Line Protocols | Modbus RTU (variant dependent) |
| Enclosure Protection Rating | Up to IP65 sealed field enclosure standard |
| Operating Temp Range | -20 to +60 deg C (PLC configurations) / -20 to +70 deg C (Industrial control configurations) |
| Relative Humidity Limits | 5% to 95% RH, non-condensing |
| Product Type | Digital I/O Cards |
Q: What programmatic or electrical faults manifest if the RS-485 termination resistor is omitted in a multi-drop topology?
A: Leaving the ends of the RS-485 communication line un-terminated causes high-frequency signal reflections back down the transmission wire. This echo distorts the Modbus RTU voltage waveforms, triggering immediate packet CRC errors, transmission timeouts, and intermittent node dropouts inside the supervisory PLC communication registers.
Q: Can the internal SPDT relay contacts be hot-swapped or serviced independently if the contacts fuse?
A: No, the SPDT relay mechanisms are permanently soldered directly onto the multi-layer internal printed circuit board assembly. Fusing or pitting of the contacts due to inductive back-EMF spikes requires complete isolation and replacement of the entire 51308099-100 module to restore reliable logic operations.

Despacho rápido desde nuestro inventario global para reducir el tiempo de inactividad y garantizar operaciones ininterrumpidas.
Todas las piezas provienen de fabricantes acreditados y se someten a exhaustivos controles de calidad.
Amplio stock de repuestos para automatización industrial y piezas descatalogadas, listas para su envío inmediato.
Todos los productos —incluidos los artículos obsoletos— están cubiertos por una garantía de 12 meses y una garantía de devolución de 30 días.
Todos los nombres de productos, marcas comerciales, marcas y logotipos mencionados en este sitio web son propiedad de sus respectivos dueños. Estos nombres y marcas comerciales se utilizan únicamente con fines de identificación y referencia. Somos un proveedor independiente de piezas de repuesto para automatización industrial. No somos un distribuidor autorizado, concesionario o representante de ningún fabricante. Los productos suministrados pueden incluir inventario excedente o artículos sin usar. No reclamamos ninguna afiliación o respaldo por parte de los fabricantes originales.