Oferta
| Color / Pattern |
|
| Power Source |
|
| Controller Design |
|
The GE Multilin MIFIIPI11E10HI00 operates as a dedicated hardware component for primary circuit monitoring, protective fault isolation, and back-up machine automation within industrial and utility distribution networks. Belonging to the specialized MIF II family, this microprocessor-based device functions as a primary protection node for distribution feeders while providing secondary auxiliary defense layers for localized transformers, generators, and motor arrays.
| Parameter | Specification |
|---|---|
| Model | MIFIIPI11E10HI00 |
| Brand | GE (General Electric Multilin) |
| Product Family | MIF II Series |
| Weight | 2.5 kg (5.51 lbs) net component mass |
| Operating Temp | -40 to +70 deg C continuous operational limits |
| Power Supply | 110-250 VDC or 110-230 VAC auxiliary control rail |
| Overcurrent Profile | Time-delayed overcurrent | Dual-level instantaneous overcurrent |
| Machine Protection | Thermal image tracking | Cold load pickup prevention |
| Breaker Automation | Breaker failure protection | Breaker health monitoring matrices |
| Digital Inputs | 2 fixed discrete inputs |
| Digital Outputs | 6 fixed digital outputs (user-configurable profiles) |
| Local Interface | 16x2 character LCD screen | 5-button setup keypad |
| Status Indicators | 6 operational LEDs (4 field-configurable channels) |
| Protocol Engines | Modbus RTU | IEC 60870-5-103 serial links |
| Product Type | Transmission and Distribution Relays |
Q: How does the integrated "cold load pickup" logic function prevent uncommanded nuisance trips when re-energizing a distribution feeder?
A: When a distribution feeder remains de-energized for an extended duration, restarting the line causes a significant inrush current because connected loads (such as HVAC systems or motors) lose diversity and turn on simultaneously. The cold load pickup function automatically modifies the overcurrent threshold settings or introduces specific time-delay extensions immediately following a breaker closure, preventing a nuisance trip during the transient inrush phase while maintaining system safety.
Q: What behavioral outcome occurs if the auxiliary power grid drops below the minimum 110 VAC/VDC operating threshold?
A: The input power sub-tier utilizes internal hardware voltage monitoring loops to maintain predictable relay behavior. If the incoming control voltage drops beneath the 110 V lower limit, internal lockout circuits prevent the execution of erratic logic, shifting the device into an automated safe-state shutdown and signaling a hardware fault warning over the serial bus to inform master operators.

Despacho rápido desde nuestro inventario global para reducir el tiempo de inactividad y garantizar operaciones ininterrumpidas.
Todas las piezas provienen de fabricantes acreditados y se someten a exhaustivos controles de calidad.
Amplio stock de repuestos para automatización industrial y piezas descatalogadas, listas para su envío inmediato.
Todos los productos —incluidos los artículos obsoletos— están cubiertos por una garantía de 12 meses y una garantía de devolución de 30 días.
Todos los nombres de productos, marcas comerciales, marcas y logotipos mencionados en este sitio web son propiedad de sus respectivos dueños. Estos nombres y marcas comerciales se utilizan únicamente con fines de identificación y referencia. Somos un proveedor independiente de piezas de repuesto para automatización industrial. No somos un distribuidor autorizado, concesionario o representante de ningún fabricante. Los productos suministrados pueden incluir inventario excedente o artículos sin usar. No reclamamos ninguna afiliación o respaldo por parte de los fabricantes originales.