Oferta
| Color / Pattern |
|
| Power Source |
|
| Communication Protocols |
|
| Controller Design |
|
The GE Multilin L90-H05-HTH-F8L-H6P-L8L-N6N-S6N-U6L-W75, also cataloged as the L90 Line Differential Protection Relay, operates as a dedicated hardware component for phase-segregated transmission line protection, high-speed single-pole tripping, and automated breaker reclosing synchronization within substation automation and utility grids. The microprocessor-based automation platform evaluates high-voltage overhead lines, underground cables, and tapped transformer circuits natively at the hardware tier to execute real-time power system telemetry isolation.
| Parameter | Specification |
|---|---|
| Model | L90-H05-HTH-F8L-H6P-L8L-N6N-S6N-U6L-W75 |
| Brand | GE Multilin (General Electric) |
| Series | Universal Relay (UR) Platform |
| Origin | Canada / United States |
| Product Weight | 2.5 kg (5.51 lbs) |
| Dimensions | 172 mm x 100 mm x 120 mm (Height x Width x Depth) |
| Operational Power Supply | Multi-voltage input: 110 VDC, 220 VDC, 110 VAC, 220 VAC (50/60 Hz) |
| Analog Measurement Precision | Voltage: +/- 0.5%; Current: +/- 0.5%; Power: +/- 0.5% |
| Waveform Oscillography Sampling | 64 samples per cycle resolution (up to 64 records retained in memory) |
| Sequence of Events (SOE) Capacity | 1024 time-tagged events with 0.5 ms hardware scan of digital inputs |
| Integrated Data Logger | Up to 16 configurable channels with 1 sample/cycle/channel max resolution |
| Core Protection Functions | Ground Distance (21G, 59N, 27X), Phase Distance (21P, 27X), Synchrocheck (25) |
| Multi-Ended Fault Location Accuracy | Within 2% margin of error limits |
| Ambient Operating Temperature | -40 to +70 deg C (-40 to +158 biographies F) |
| Storage Temperature Limits | -40 to +85 deg C (-40 to +185 biographies F) |
| Product Type | Protection Relays |
Q: How does the L90 relay perform phase-segregated fault identification under transient line imbalances?
A: The relay uses high-speed analog sampling at 64 samples per cycle to resolve localized voltage and current vectors independently for each individual phase. If a phase-to-ground or phase-to-phase transient breaches programmed graphical zone boundaries, the unit instantly targets the faulted path, triggering standalone single-pole breaker execution without de-energizing clean phases.
Q: What defensive hardware metrics manifest if local infrastructure security settings are breached?
A: The onboard network security layers deploy hardware dual-permission access control and centralized command logging. Any unauthorized network communication or manual configuration alteration attempts outside of verified security credentials instantly lock local terminal control and set an active cybersecurity log alert entry over the substation bus link.

Despacho rápido desde nuestro inventario global para reducir el tiempo de inactividad y garantizar operaciones ininterrumpidas.
Todas las piezas provienen de fabricantes acreditados y se someten a exhaustivos controles de calidad.
Amplio stock de repuestos para automatización industrial y piezas descatalogadas, listas para su envío inmediato.
Todos los productos —incluidos los artículos obsoletos— están cubiertos por una garantía de 12 meses y una garantía de devolución de 30 días.
Todos los nombres de productos, marcas comerciales, marcas y logotipos mencionados en este sitio web son propiedad de sus respectivos dueños. Estos nombres y marcas comerciales se utilizan únicamente con fines de identificación y referencia. Somos un proveedor independiente de piezas de repuesto para automatización industrial. No somos un distribuidor autorizado, concesionario o representante de ningún fabricante. Los productos suministrados pueden incluir inventario excedente o artículos sin usar. No reclamamos ninguna afiliación o respaldo por parte de los fabricantes originales.