The GE Fanuc IC670ALG330, also cataloged as the IC670 Analog Output Module, operates as a dedicated hardware component for continuous variable signal generation within Field Control I/O stations. The sub-assembly drives 8 single-ended current source outputs natively at the hardware tier to actuate control valves, variable speed drives, and analog chart recorders across modular expansion frameworks.
| Parameter | Specification |
|---|---|
| Model | IC670ALG330 |
| Brand | GE Fanuc Emerson |
| Origin | USA |
| Weight | 0.56 lbs (0.26 kg) |
| Wiring Configuration | Single-ended |
| Series | Field I/O control |
| Channel Density | 8 Current Source outputs |
| Signal Type | Analog Current (Sourcing) |
| Output Signal Nominal | 0 to 20 mA |
| Output Signal Range | 0.0 to 20.48 mA |
| Digital-to-Analog Resolution | 16 bits (0.3125 uA per count maximum resolution) |
| Magnitude Data Size | 14 bits |
| Linearity | 1 LSB resolution value |
| Update Time | 1.5 ms typical per channel |
| Output Load Capacitance | 2000 pF maximum |
| Output Load Inductance | 0.5 H maximum |
| Open Wire Threshold | 1.0 mA minimum, 3.5 mA maximum |
| Dielectric Isolation Limit | 1500 VAC for 1 minute / 250 VAC continuous (to ground and logic) |
| Nominal Supply Voltage | 24 VDC typical (18 to 30 VDC allowable range, 10% maximum ripple) |
| BIU Power Consumption | 85 mA maximum current drawn from Bus Interface Unit backplane |
| External Power Consumption | 250 mA maximum drawn from external supply (all 8 outputs at 20 mA) |
| Status Diagnostics | 1 LED indicator (Steady = OK, Flashing = Fault, Off = No Power/Fatal) |
| Product Type | Analog Output Modules |
Q: What technical fault diagnostics trigger an alarm flag on the IC670ALG330?
A: The internal processing architecture continually validates output loop continuity. The hardware generates distinct diagnostic alarm registers and passes error codes across the backplane bus to the BIU when encountering under-range signals, over-range exceptions, or an open-wire field fault where current falls below the 1.0 to 3.5 mA threshold.
Q: Can the module calibration parameters be recovered if the configuration becomes corrupted?
A: Yes, the module features on-board non-volatile flash memory that archives the factory calibration data baselines. Users can clear custom field scaling parameters via configuration commands to restore the module directly to its factory-calibrated current output settings.

Despacho rápido desde nuestro inventario global para reducir el tiempo de inactividad y garantizar operaciones ininterrumpidas.
Todas las piezas provienen de fabricantes acreditados y se someten a exhaustivos controles de calidad.
Amplio stock de repuestos para automatización industrial y piezas descatalogadas, listas para su envío inmediato.
Todos los productos —incluidos los artículos obsoletos— están cubiertos por una garantía de 12 meses y una garantía de devolución de 30 días.
Todos los nombres de productos, marcas comerciales, marcas y logotipos mencionados en este sitio web son propiedad de sus respectivos dueños. Estos nombres y marcas comerciales se utilizan únicamente con fines de identificación y referencia. Somos un proveedor independiente de piezas de repuesto para automatización industrial. No somos un distribuidor autorizado, concesionario o representante de ningún fabricante. Los productos suministrados pueden incluir inventario excedente o artículos sin usar. No reclamamos ninguna afiliación o respaldo por parte de los fabricantes originales.