Configured for high-density data aggregation, Remote Terminal Unit (RTU) operations, and programmable logic execution within electrical substation networks, the GE Fanuc D25-0158-000002 (D25-0158-000002 Multi-Functional Controller) provides direct physical/electrical execution. It processes multi-channel analog and digital inputs natively at the backplane tier to track substation telemetry parallel to master control network platforms.
| Parameter | Specification |
|---|---|
| Model | D25-0158-000002 |
| Brand | GE Fanuc / GE Multilin |
| Origin | Canada / United States |
| Dimensions | 19-inch rack mount configuration x 8.75 inches (22.22 cm) high |
| Operating Temp | Calibrated for standard utility substation environmental limits |
| Power Consumption | Regulated by internal transformation logic bus |
| Digital Status Inputs | Configurable from 0 to 96 channels in 32-input increments |
| Control Outputs | Configurable from 0 to 32 trip/close pairs |
| AC Analog Inputs | Configurable options: 0, 3, 6, 9, 12, or 15 inputs |
| DC Analog Inputs | Configurable options: 0, 8, or 16 inputs |
| Serial Communications | 2 x Host ports (38.4 Kbps), 2 x IED ports (38.4 Kbps), 1 x WESMAINT config port |
| Ethernet Interfaces | 2 x Host ports (10 Mbps hardware configuration) |
| Local Operator Display | 1 x Dedicated D25 Display Port (9600 bps) |
| Time Synchronization | 1 x Dedicated IRIG / Rugby / GPS synchronization interface |
Q: What technical tracking behavior manifests across the substation network if the device loses its external timing synchronization source?
A: The internal time clock shifts immediately to a free-running state based on its local crystal oscillator. The controller flags a "Time Sync Lost" diagnostic bit in its status register and marks all subsequent Sequence of Events (SOE) data logs with an un-synchronized tracking attribute until the IRIG/GPS signal is restored.
Q: Can the internal input/output cards be hot-swapped while the 19-inch rack chassis is fully energized?
A: No. The internal sub-assembly card interfaces do not feature staggered pin geometry configured for live hot-swapping under electrical load. Pulling or inserting cards while backplane logic power is applied can induce transient arcs across data traces, risking permanent physical damage to components and corrupting active system memory.

Despacho rápido desde nuestro inventario global para reducir el tiempo de inactividad y garantizar operaciones ininterrumpidas.
Todas las piezas provienen de fabricantes acreditados y se someten a exhaustivos controles de calidad.
Amplio stock de repuestos para automatización industrial y piezas descatalogadas, listas para su envío inmediato.
Todos los productos —incluidos los artículos obsoletos— están cubiertos por una garantía de 12 meses y una garantía de devolución de 30 días.
Todos los nombres de productos, marcas comerciales, marcas y logotipos mencionados en este sitio web son propiedad de sus respectivos dueños. Estos nombres y marcas comerciales se utilizan únicamente con fines de identificación y referencia. Somos un proveedor independiente de piezas de repuesto para automatización industrial. No somos un distribuidor autorizado, concesionario o representante de ningún fabricante. Los productos suministrados pueden incluir inventario excedente o artículos sin usar. No reclamamos ninguna afiliación o respaldo por parte de los fabricantes originales.