| Color / Pattern |
|
| Power Source |
|
| Communication Protocols |
|
| Controller Design |
|
The Yokogawa SARM55C, also cataloged as the SARM55C Terminal Board, operates as a dedicated hardware component for multi-channel discrete output execution, plant interlock actuation, and field device interfacing within Yokogawa industrial control platforms. Configured with 32 relay output channels supporting Form A or Form C electromechanical variations, the solid-state sub-assembly provides direct physical/electrical execution to convert low-level control signals into isolated, relay-driven outputs natively at the hardware tier.
| Parameter | Specification |
|---|---|
| Model | SARM55C Terminal Board |
| Brand | Yokogawa |
| Origin | Japan |
| Weight | 2.2 kg (4.85 lbs) net component mass |
| Dimensions | Standard rack-mounted I/O frame layout dimensions |
| Operating Temp | -20 to +70 deg C continuous operational limits |
| Humidity Range | Non-condensing industrial tolerance parameters |
| Rated Voltage | 24 V DC field-supplied auxiliary control input |
| Output Capacity | 32 independent relay contact pathways |
| Contact Form | Form A (Normally Open) or Form C (Changeover) depending on variant |
| Isolation Barrier | Full channel-to-channel and channel-to-system isolation |
| Load Protection | Integrated inductive load suppression circuit arrays |
| Field Interface | Heavy-duty M4 screw terminal configurations |
| Coating Option | Industrial-grade PCB construction with protective coating |
| Product Type | Digital I/O Cards |
Q: How does the integrated inductive load suppression circuit maintain relay lifespan?
A: Switching inductive field elements like solenoids, contactor coils, or control valves generates a high-voltage back-EMF spike when the relay contacts open. The embedded suppression network clamps these transient voltage peaks natively at the hardware tier, eliminating electrical arcing across the physical contact gaps to prevent pitting, material transfer, and premature contact welding during continuous plant runtime.
Q: What behavioral outcome occurs if the field-supplied 24 V DC power network falls below nominal voltage thresholds?
A: The board relies on an external 24 V DC supply to energize the electromechanical relay coils across the 32 discrete paths. If this external field voltage drops significantly below nominal operational parameters, the internal coil holding force decreases, which can cause contact chatter, intermittent state tracking, or an automated return to the de-energized safe state across all active output loops.

إرسال سريع من مخزوننا العالمي لتقليل وقت التوقف وضمان العمليات دون انقطاع.
جميع الأجزاء مصدرها شركات مصنعة ذات سمعة طيبة وتخضع لفحوصات جودة شاملة.
مخزون واسع النطاق من الأتمتة الصناعية والأجزاء المتوقفة، جاهزة للشحن الفوري.
يتم تغطية كل منتج - بما في ذلك المنتجات القديمة - بضمان لمدة 12 شهرًا وضمان إرجاع لمدة 30 يومًا.
جميع أسماء المنتجات والعلامات التجارية والشعارات المذكورة في هذا الموقع هي ملك لأصحابها. تُستخدم هذه الأسماء والعلامات التجارية لأغراض التعريف والمراجع فقط. نحن مورد مستقل لقطع غيار الأتمتة الصناعية. لسنا موزعًا أو تاجرًا أو ممثلاً معتمدًا لأي مصنع. قد تشمل المنتجات الموردة مخزونًا فائضًا أو عناصر غير مستخدمة. لا ندعي أي انتماء أو تأييد من قبل المصنعين الأصليين.