أُوكَازيُون
أُوكَازيُون
The GE Multilin UR SHA is a third‑generation high‑voltage power supply module for Universal Relay (UR) systems. It replaces the earlier UR‑1H and UR‑RH modules, delivering higher output power, improved thermal performance, and enhanced isolation ratings. As part of the UR modular architecture, the UR‑SHA installs behind the relay’s hinged faceplate and provides regulated power to both the relay chassis and its dry‑contact input circuits.
| Parameter | Specification |
|---|---|
| Model | UR‑SHA |
| Manufacturer | GE Multilin |
| Origin | Markham, Ontario, Canada |
| Weight | approx. 2 lb 2 oz |
| Dimensions | 6.5 in × 6.5 in × 1.75 in |
| Voltage Range | 125–250 V DC (nominal) • 100–240 V AC (50/60 Hz) |
| Output Power | 45 W (increased from 35 W in earlier generations) |
| Dry Contact Input Power | 48 V DC |
| Isolation Voltage | 2300 V AC |
| Environmental Option | “A” = Horizontal 19‑inch rack, harsh‑environment coating |
| Software Support | EnerVista UR |
The UR‑SHA is one of the most advanced power‑supply modules in the UR family. It provides:
The module is designed to operate reliably in demanding industrial and utility environments. Its built‑in protection features include:
UR relays continuously monitor the health of the UR‑SHA using internal diagnostics. Any detected fault triggers:
The UR‑SHA belongs to the UR‑SH generation, replacing earlier modules:
| Feature | UR‑1H (Gen 1) | UR‑RH (Gen 2) | UR‑SHA (Gen 3) |
|---|---|---|---|
| Output Power | 35 W | 35 W | 45 W |
| Isolation Voltage | 2000 V AC | 2000 V AC | 2300 V AC |
| Heat Efficiency | Standard | Standard | 28% improved |
| Over‑Temp Protection | No | No | Yes (105°C shutdown) |
| Capacitor Count | 27 electrolytic | 27 electrolytic | 1 electrolytic (high‑reliability design) |
| Input Voltage Range (DC) | 88–300 V | 88–300 V | 88–400 V |
In UR‑SHA, the suffix A indicates:
If the suffix were B, it would indicate:
Q: How is the UR‑SHA different from earlier UR power supplies? A: It provides higher output power (45 W), better efficiency, improved isolation, and over‑temperature protection.
Q: What does the “A” in UR‑SHA mean? A: It specifies a horizontal 19‑inch rack version with harsh‑environment coating.
Q: What voltage does the UR‑SHA supply to dry‑contact inputs? A: It provides 48 V DC for dry‑contact input circuits.

إرسال سريع من مخزوننا العالمي لتقليل وقت التوقف وضمان العمليات دون انقطاع.
جميع الأجزاء مصدرها شركات مصنعة ذات سمعة طيبة وتخضع لفحوصات جودة شاملة.
مخزون واسع النطاق من الأتمتة الصناعية والأجزاء المتوقفة، جاهزة للشحن الفوري.
يتم تغطية كل منتج - بما في ذلك المنتجات القديمة - بضمان لمدة 12 شهرًا وضمان إرجاع لمدة 30 يومًا.
جميع أسماء المنتجات والعلامات التجارية والشعارات المذكورة في هذا الموقع هي ملك لأصحابها. تُستخدم هذه الأسماء والعلامات التجارية لأغراض التعريف والمراجع فقط. نحن مورد مستقل لقطع غيار الأتمتة الصناعية. لسنا موزعًا أو تاجرًا أو ممثلاً معتمدًا لأي مصنع. قد تشمل المنتجات الموردة مخزونًا فائضًا أو عناصر غير مستخدمة. لا ندعي أي انتماء أو تأييد من قبل المصنعين الأصليين.