Configured for high‑density 24 VDC discrete acquisition in MasterLogic platforms, the Honeywell 2MLI‑D28A (2MLI‑D28A digital input module) provides direct electrical execution of 64 sinking‑type input points with CPU‑configurable response timing and photo‑coupler isolation.
| Parameter | Specification |
|---|---|
| Model | 2MLI‑D28A |
| Brand | Honeywell |
| Origin | Not specified |
| Weight | 0.15 kg |
| Dimensions | Not specified |
| Operating Temp | Not specified |
| Power Consumption | 60 mA |
| Product Type | Digital Input Modules |
| Series | MasterLogic |
| Number of Input Points | 64 |
| Isolation Method | Photo‑coupler isolation |
| Rated Input Voltage | 24 VDC |
| Rated Input Current | ~4 mA |
| Operating Voltage Range | 20.4–28.8 VDC (ripple < 5%) |
| Input Resistance | ~5.6 kΩ |
| ON Threshold | ≥19 V / ≥3 mA |
| OFF Threshold | ≤11 V / ≤1.7 mA |
| Response Time | 1/3/5/10/20/70/100 ms (CPU‑set), default 3 ms |
| Isolation Voltage | AC 560 V rms (3 cycles @ 2000 m altitude) |
| Isolation Resistance | ≥10 MΩ |
| Common Method | 32‑point per COM |
| Cable Size | 0.3 mm² |
| Indicators | 32‑point LED bank (switch‑selectable) |
| External Connection | Two 40‑point connectors |
Although the 2MLI‑D28A is a discrete module, its photo‑coupler isolation and threshold design align with Honeywell’s mixed‑signal backplane behavior. Channel‑to‑channel isolation prevents transient coupling from adjacent analogue modules handling 4‑20 mA HART loops. The module’s fixed impedance (~5.6 kΩ) ensures predictable loading when installed near loop‑powered transmitters, while the AC 560 V isolation rating maintains stable reference behavior across grounding planes. CPU‑selectable response times allow tuning for noise‑sensitive environments where HART loop polling may introduce switching artifacts.
Q: Can the 2MLI‑D28A be hot‑swapped? A: No. The module must be inserted or removed only when the MasterLogic rack is de‑energized.
Q: Does changing the CPU response‑time parameter affect backplane timing? A: No. Response‑time selection affects only input filtering; backplane scan timing is controlled by the CPU.
Q: Are the 64 points individually isolated? A: Isolation is provided per channel through photo‑couplers, but commons are grouped in 32‑point COM blocks.

إرسال سريع من مخزوننا العالمي لتقليل وقت التوقف وضمان العمليات دون انقطاع.
جميع الأجزاء مصدرها شركات مصنعة ذات سمعة طيبة وتخضع لفحوصات جودة شاملة.
مخزون واسع النطاق من الأتمتة الصناعية والأجزاء المتوقفة، جاهزة للشحن الفوري.
يتم تغطية كل منتج - بما في ذلك المنتجات القديمة - بضمان لمدة 12 شهرًا وضمان إرجاع لمدة 30 يومًا.
جميع أسماء المنتجات والعلامات التجارية والشعارات المذكورة في هذا الموقع هي ملك لأصحابها. تُستخدم هذه الأسماء والعلامات التجارية لأغراض التعريف والمراجع فقط. نحن مورد مستقل لقطع غيار الأتمتة الصناعية. لسنا موزعًا أو تاجرًا أو ممثلاً معتمدًا لأي مصنع. قد تشمل المنتجات الموردة مخزونًا فائضًا أو عناصر غير مستخدمة. لا ندعي أي انتماء أو تأييد من قبل المصنعين الأصليين.