The GE WESDAC D20S, also cataloged as the D20S Substation Controller, operates as a dedicated hardware component for executing localized automation algorithms and managing data collection within high-voltage substation networks.
| Parameter | Specification |
|---|---|
| Model | D20S |
| Brand | GE (General Electric / Wescom) |
| Series | WESDAC / D20 Series |
| Origin | United States (US) |
| Weight | Configuration dependent (Varies based on card layout and module population) |
| Dimensions | Standard 19" rack-mountable chassis assembly |
| Operating Temp | -20 to +70 deg C (-4 to +158 deg F) standard substation envelope |
| Power Consumption | Input options: 20-60 VDC, 100-300 VDC, or 85-264 VAC configuration paths |
| CPU Architecture | 32-bit microprocessor processing core |
| Flash Memory | 2 MB flash application memory |
| SRAM | 1.5 MB static random-access memory (volatile data registers) |
| NVRAM | 512 KB non-volatile random-access memory |
| BootROM | 1 MB integrated boot read-only memory |
| Serial Interfaces | 7 RS-232/485 serial ports |
| I/O Bus Interface | 2 D.20 Link HDLC ports for dedicated I/O module connection |
| Network Infrastructure | Optional Ethernet port allocation with redundancy support |
| I/O Module Capacity | Supports scaling up to a maximum of 120 distributed D20 I/O modules |
| Compliance Standards | EN 61000-6-2 (Immunity), EN 61000-6-4 (Emission) industrial metrics |
Q: How does the D20S handle data integrity verification within its internal volatile storage matrices?
A: The 32-bit architecture runs continuous hardware-level cyclic redundancy checks (CRC) and memory parity validation routines across the 1.5 MB SRAM block. If a memory cell data error or parity exception manifests during calculation execution, the CPU flags the mismatch in the diagnostic database and can trigger an immediate failover switch if an optional redundant processor chassis is physically online.
Q: Can the 7 serial ports be hot-configured or wired while the controller is executing live substation automation loops?
A: Yes, serial communication lines may be connected or disconnected without halting processor execution. However, changing port configurations (such as baud rates or protocol types) in the system parameters requires downloading a modified configuration via the GE software suite, which clears and reinitializes the active serial port buffers.

إرسال سريع من مخزوننا العالمي لتقليل وقت التوقف وضمان العمليات دون انقطاع.
جميع الأجزاء مصدرها شركات مصنعة ذات سمعة طيبة وتخضع لفحوصات جودة شاملة.
مخزون واسع النطاق من الأتمتة الصناعية والأجزاء المتوقفة، جاهزة للشحن الفوري.
يتم تغطية كل منتج - بما في ذلك المنتجات القديمة - بضمان لمدة 12 شهرًا وضمان إرجاع لمدة 30 يومًا.
جميع أسماء المنتجات والعلامات التجارية والشعارات المذكورة في هذا الموقع هي ملك لأصحابها. تُستخدم هذه الأسماء والعلامات التجارية لأغراض التعريف والمراجع فقط. نحن مورد مستقل لقطع غيار الأتمتة الصناعية. لسنا موزعًا أو تاجرًا أو ممثلاً معتمدًا لأي مصنع. قد تشمل المنتجات الموردة مخزونًا فائضًا أو عناصر غير مستخدمة. لا ندعي أي انتماء أو تأييد من قبل المصنعين الأصليين.