The Multilin PQM-T20-C-A, also cataloged as the PQMT20CA Power Quality Meter, operates as a dedicated hardware component for continuous electrical parameters monitoring and power quality analysis within GE Multilin power management networks.
| Parameter | Specification |
|---|---|
| Model | PQM-T20-C-A (PQMT20CA) |
| Brand | Multilin (GE) |
| Origin | Canada |
| Weight | 3.00 lbs (1.36 kg) |
| Dimensions | Standard 1/8 DIN Cutout Mount (Enclosure Specs) |
| Operating Temp | -20 to 60 deg C |
| Power Consumption | 10 W maximum |
| Input Voltage | 90-265 VAC / 100-300 VDC Nominal |
| Measured Parameters | Voltage, Current, Power (KW, KVA, KVAR), Frequency, THD |
| Serial Interface | RS-485 / RS-232 Serial Communication Ports |
| Analog Inputs | (1) 4-20 mA Analog Input |
| Analog Outputs | (4) Isolated 0-20 mA / 4-20 mA Analog Outputs |
| Display Type | Front Panel LED Numeric Display |
The Multilin PQM-T20-C-A features four fully isolated 0-20 mA or 4-20 mA analog output channels designed for proportional signal retransmission to plant DCS and SCADA networks. Galvanic channel-to-channel isolation eliminates ground loop interference across long-distance current loops, preserving measurement accuracy for voltage, current, and active power quantities. The onboard analog processing hardware converts digitized high-speed sampling data into continuous analog loop current outputs, ensuring real-time signal tracking and deterministic updating for downstream automation controllers.
Q: What power quality and electrical variables are calculated by the PQM-T20-C-A terminal?
A: The meter continuously samples real-time system voltage and current waveforms to calculate active power (kW), reactive power (kVAR), apparent power (kVA), total harmonic distortion (THD), and system frequency.
Q: How are the analog output current signals configured on the PQM-T20-C-A?
A: The four isolated output channels can be software-configured via front-panel programming or serial commands to output either 0-20 mA or 4-20 mA current loops mapped to specific measured electrical parameters.
Mount the unit securely into a standard panel cutout, verifying that the front panel gasket is fully compressed to prevent dust and moisture ingress. Ensure current transformer (CT) secondary circuits are connected through shorting blocks and solidly grounded at a single point before powering the device. All serial RS-485 communication lines must use shielded twisted-pair cabling terminated with a 120 ohm resistor across the end nodes to suppress signal reflections and noise coupling.

إرسال سريع من مخزوننا العالمي لتقليل وقت التوقف وضمان العمليات دون انقطاع.
جميع الأجزاء مصدرها شركات مصنعة ذات سمعة طيبة وتخضع لفحوصات جودة شاملة.
مخزون واسع النطاق من الأتمتة الصناعية والأجزاء المتوقفة، جاهزة للشحن الفوري.
يتم تغطية كل منتج - بما في ذلك المنتجات القديمة - بضمان لمدة 12 شهرًا وضمان إرجاع لمدة 30 يومًا.
جميع أسماء المنتجات والعلامات التجارية والشعارات المذكورة في هذا الموقع هي ملك لأصحابها. تُستخدم هذه الأسماء والعلامات التجارية لأغراض التعريف والمراجع فقط. نحن مورد مستقل لقطع غيار الأتمتة الصناعية. لسنا موزعًا أو تاجرًا أو ممثلاً معتمدًا لأي مصنع. قد تشمل المنتجات الموردة مخزونًا فائضًا أو عناصر غير مستخدمة. لا ندعي أي انتماء أو تأييد من قبل المصنعين الأصليين.