Configured for rack expansion and system fault isolation in GE Series Nine Seven control systems, the GE IC697BEM711N (IC697BEM711N Bus Interface Module) provides direct physical/electrical execution.
| Suffix / Identifier | Technical Description / Hardware State |
|---|---|
| IC697 | Base platform designation indicating Series 97 PLC and high-performance rack infrastructure. |
| BEM | Core functional identifier denoting the Bus Interface Module architecture. |
| 711 | Specific model suffix designating the bus receiver hardware variant and port configuration. |
| N | Revision and manufacturing variant suffix indicating specific component build state. |
| Parameter | Specification |
|---|---|
| Model | IC697BEM711N |
| Brand | GE |
| Origin | USA |
| Weight | 0.8 kg |
| Dimensions | Standard IC697 double-wide VME module format |
| Operating Temp | 0 deg C to +60 deg C |
| Power Consumption | Powered via IC697 rack backplane bus |
| Communication Interfaces | Two (2) serial communication expansion ports |
| Maximum Distance | Up to 50 feet (15 meters) between modules |
The module communicates via high-speed backplane and external serial links to manage up to seven expansion racks deterministically. Firmware flash compatibility is maintained through onboard memory components that synchronize data transmission across the expansion bus. Backplane bus communication velocity operates within precise timing limits to transmit low-level signals representing expansion rack I/O data without propagation errors. I/O density scaling supports extensive remote rack expansion while ensuring isolated fault handling and state retention across faulted nodes.
Q: What is the maximum allowable communication distance between interconnected BEM 711 or BEM 713 modules?
A: The maximum allowable cable distance between each BEM 711 or BEM 713 module is 50 feet or 15 meters.
Q: How does the module handle output states during a rack fault or maintenance procedure?
A: It supports output retention, allowing the output modules of the isolated or faulty rack to maintain their individual final state.
Q: What are the primary functions of the two communication ports on the front faceplate?
A: Port 1 is utilized for establishing connections with the CPU or upstream BEM modules, while the second interface connects downstream expansion racks or additional BEM 711 units.

إرسال سريع من مخزوننا العالمي لتقليل وقت التوقف وضمان العمليات دون انقطاع.
جميع الأجزاء مصدرها شركات مصنعة ذات سمعة طيبة وتخضع لفحوصات جودة شاملة.
مخزون واسع النطاق من الأتمتة الصناعية والأجزاء المتوقفة، جاهزة للشحن الفوري.
يتم تغطية كل منتج - بما في ذلك المنتجات القديمة - بضمان لمدة 12 شهرًا وضمان إرجاع لمدة 30 يومًا.
جميع أسماء المنتجات والعلامات التجارية والشعارات المذكورة في هذا الموقع هي ملك لأصحابها. تُستخدم هذه الأسماء والعلامات التجارية لأغراض التعريف والمراجع فقط. نحن مورد مستقل لقطع غيار الأتمتة الصناعية. لسنا موزعًا أو تاجرًا أو ممثلاً معتمدًا لأي مصنع. قد تشمل المنتجات الموردة مخزونًا فائضًا أو عناصر غير مستخدمة. لا ندعي أي انتماء أو تأييد من قبل المصنعين الأصليين.