أُوكَازيُون
أُوكَازيُون
| Color / Pattern |
|
| Power Source |
|
| Communication Protocols |
|
| Controller Design |
|
Configured for precision shaft vibration and displacement monitoring in AMS EZ1000 monitoring networks, the Emerson EZ1080-04-00-010 (EZ1080-04-00-010 Eddy Current Sensor) provides direct physical/electrical execution.
| Suffix Segment | Parameter Designation | Description & Configuration |
|---|---|---|
| EZ1080 | Series Code | AMS EZ1000 8 mm eddy current probe platform |
| 04 | Probe Length Code | 40 mm probe body length variant |
| 00 | Cable Length Option | 1 meter integral cable variant |
| 010 | Connector & Thread Option | M10 x 1 threaded body with standard industrial termination |
| Parameter | Specification |
|---|---|
| Model | EZ1080-04-00-010 |
| Brand | Emerson |
| Origin | USA / Global Manufacturing Facility |
| Weight | 0.15 kg (approximate with cable) |
| Dimensions | 40 mm probe length, M10 x 1 thread size |
| Operating Temp | -35 deg C to +180 deg C |
| Power Consumption | Powered via EZ1000 Eddy Current Converter |
| Tip Diameter | 8 mm |
| Cable Type | Non-armored coaxial cable (1 meter length) |
| Protection Rating | IP67 (fully submersible probe tip) |
The probe operates by emitting a high-frequency electromagnetic field from its tip coil into the conductive target surface of the rotating shaft, inducing eddy currents that alter coil impedance proportional to the gap distance. Calibration scaling targets a nominal -10 VDC centerline gap voltage midpoint, producing a standard sensitivity output of 7.87 mV/micron (200 mV/mil) through the mated EZ1000 converter module. This linearity enables real-time monitoring of radial vibration, rotor dynamic behavior, and axial position shifts. Cross-talk suppression is maintained through proper physical spacing rules and coaxial shielding terminations, preventing signal distortion when multiple probes are installed closely on complex machinery trains.
Q: What is the required gap voltage calibration target during initial mechanical setup?
A: The probe gap should be adjusted mechanically until the static output voltage reaches -10 VDC, corresponding to the linear middle range of the transducer characteristic curve.
Q: Can the 1 meter integral cable be shortened or spliced in the field?
A: No. The probe assembly, integral cable, and converter module are calibrated as a matched electrical system. Altering cable length changes total capacitance and destroys output calibration accuracy.
Q: What is the minimum target size required for accurate vibration measurement?
A: The rotating shaft target diameter must be at least three times the probe tip diameter (minimum 24 mm for an 8 mm tip) to prevent edge effect errors on the eddy-current field.

إرسال سريع من مخزوننا العالمي لتقليل وقت التوقف وضمان العمليات دون انقطاع.
جميع الأجزاء مصدرها شركات مصنعة ذات سمعة طيبة وتخضع لفحوصات جودة شاملة.
مخزون واسع النطاق من الأتمتة الصناعية والأجزاء المتوقفة، جاهزة للشحن الفوري.
يتم تغطية كل منتج - بما في ذلك المنتجات القديمة - بضمان لمدة 12 شهرًا وضمان إرجاع لمدة 30 يومًا.
جميع أسماء المنتجات والعلامات التجارية والشعارات المذكورة في هذا الموقع هي ملك لأصحابها. تُستخدم هذه الأسماء والعلامات التجارية لأغراض التعريف والمراجع فقط. نحن مورد مستقل لقطع غيار الأتمتة الصناعية. لسنا موزعًا أو تاجرًا أو ممثلاً معتمدًا لأي مصنع. قد تشمل المنتجات الموردة مخزونًا فائضًا أو عناصر غير مستخدمة. لا ندعي أي انتماء أو تأييد من قبل المصنعين الأصليين.