أُوكَازيُون
أُوكَازيُون
| Color / Pattern |
|
The Bently Nevada 330703-000-040-10-02-00, also cataloged as the 330703 11 mm Eddy Current Probe, operates as a dedicated hardware component for non-contact shaft displacement and rotor dynamics monitoring within 3500 Machinery Protection Systems.
| Parameter | Specification |
|---|---|
| Model | 330703-000-040-10-02-00 |
| Brand | Bently Nevada |
| Series | 3300 XL 11 mm Series |
| Product Type | Proximity Probe Transducer |
| Mounting Thread | M14 x 1.5 |
| Unthreaded Length | 0 mm |
| Overall Case Length | 40 mm |
| System Total Length | 1.0 meter (3.3 feet) |
| Cable / Connector Type | Standard cable with ClickLoc coaxial connector |
| Linear Measurement Range | 4.0 mm (160 mils) |
| Scale Factor Output | 3.94 V/mm (100 mV/mil) |
| Target Material Standard | AISI 4140 Steel |
| Probe Tip Material | Polyphenylene sulfide (PPS) |
| Operating Temp | -52 to 177 deg C |
| Probe DC Resistance | 5.9 +/- 0.5 ohms (center to outer conductor at 1 m) |
The 330703-000-040-10-02-00 transducer operates on the high-frequency eddy-current principle to measure shaft position and rotor dynamics relative to machine bearing structures. The system maintains an Incremental Scale Factor (ISF) of 3.94 V/mm (100 mV/mil) when paired with a matching 3300 XL 11 mm Proximitor Sensor powered by -24 VDC. Precise gap voltage validation (targeting -10 VDC at mid-span gap settings) ensures optimal magnetic field density and prevents signal distortion during dynamic rotor excursions. The triaxial cable geometry incorporates high-density braid shielding to achieve cross-talk suppression and immunity from adjacent channel high-frequency radio frequency interference.
Q: What gap voltage reading corresponds to the center of the linear operating range for the 3300 XL 11 mm probe?
A: Setting the probe gap to approximately 2.5 mm (100 mils) yields a baseline DC gap voltage of -10 VDC at the Proximitor Sensor output terminals.
Q: Can the ClickLoc connector on the 330703-000-040-10-02-00 probe lead be disconnected while the monitoring circuit is energized?
A: The connector should not be unlatched while power is applied unless the area is confirmed to be non-hazardous, as physical disconnection may break intrinsic safety barrier loops.

إرسال سريع من مخزوننا العالمي لتقليل وقت التوقف وضمان العمليات دون انقطاع.
جميع الأجزاء مصدرها شركات مصنعة ذات سمعة طيبة وتخضع لفحوصات جودة شاملة.
مخزون واسع النطاق من الأتمتة الصناعية والأجزاء المتوقفة، جاهزة للشحن الفوري.
يتم تغطية كل منتج - بما في ذلك المنتجات القديمة - بضمان لمدة 12 شهرًا وضمان إرجاع لمدة 30 يومًا.
جميع أسماء المنتجات والعلامات التجارية والشعارات المذكورة في هذا الموقع هي ملك لأصحابها. تُستخدم هذه الأسماء والعلامات التجارية لأغراض التعريف والمراجع فقط. نحن مورد مستقل لقطع غيار الأتمتة الصناعية. لسنا موزعًا أو تاجرًا أو ممثلاً معتمدًا لأي مصنع. قد تشمل المنتجات الموردة مخزونًا فائضًا أو عناصر غير مستخدمة. لا ندعي أي انتماء أو تأييد من قبل المصنعين الأصليين.