أُوكَازيُون
أُوكَازيُون
Configured for precise shaft angular position and speed measurement in industrial control networks, the Allen-Bradley 845T-HC12PFW-1 (845T-HC12PFW) Optical Rotary Encoder provides direct physical/electrical execution. The heavy-duty encoder converts rotational mechanical motion into dual-channel quadrature digital signals via a 1024 PPR optical disk, delivering 5 VDC Differential Line Driver (DLD) outputs over a 1-meter pigtail cable.
| Parameter | Specification |
|---|---|
| Model | 845T-HC12PFW-1 |
| Brand | Allen-Bradley |
| Series | Bulletin 845T |
| Category | Encoders / Optical Rotary Encoders |
| Origin | USA |
| Weight | 3.00 lbs (1.36 kg) |
| Dimensions | Servo Mount Heavy-Duty Shaft Assembly |
| Operating Temp | -20 to 65 deg C |
| Power Consumption | 5 VDC Input |
| Resolution | 1024 PPR (Pulses Per Revolution) |
| Shaft Specification | 1/4 inch Diameter |
| Output Signal Type | 5 VDC Differential Line Driver (DLD), Channel A & B |
| Connection Type | 1 m (3.28 ft) Pigtail Cable |
The 845T-HC12PFW-1 interfaces with high-speed counter cards and drive feedback loops to support I/O density scaling and deterministic motion execution within Allen-Bradley Logix platforms. Differential line driver channels (A, B, and inverse signals) transmit high-frequency quadrature pulses that maintain high signal-to-noise ratios over extended cable runs. This high-density feedback architecture enables PLC and drive modules to execute closed-loop velocity calculation and position tracking without phase distortion or signal loss.
Q: Can the 845T-HC12PFW-1 5 VDC line driver output be wired directly to a 24 VDC PLC input card?
A: No, connecting 5 VDC Differential Line Driver outputs to a 24 VDC input module will result in signal failure or channel damage. A 5 VDC to 24 VDC level converter card or a compatible 5 VDC differential counter module must be used.
Q: How are cable shield terminations handled to prevent noise on quadrature channels A and B?
A: The pigtail cable shield must be grounded at a single point at the receiving control cabinet earth ground bus. The shield should remain isolated and ungrounded at the encoder housing to prevent ground loop currents from interfering with pulse transmission.

إرسال سريع من مخزوننا العالمي لتقليل وقت التوقف وضمان العمليات دون انقطاع.
جميع الأجزاء مصدرها شركات مصنعة ذات سمعة طيبة وتخضع لفحوصات جودة شاملة.
مخزون واسع النطاق من الأتمتة الصناعية والأجزاء المتوقفة، جاهزة للشحن الفوري.
يتم تغطية كل منتج - بما في ذلك المنتجات القديمة - بضمان لمدة 12 شهرًا وضمان إرجاع لمدة 30 يومًا.
جميع أسماء المنتجات والعلامات التجارية والشعارات المذكورة في هذا الموقع هي ملك لأصحابها. تُستخدم هذه الأسماء والعلامات التجارية لأغراض التعريف والمراجع فقط. نحن مورد مستقل لقطع غيار الأتمتة الصناعية. لسنا موزعًا أو تاجرًا أو ممثلاً معتمدًا لأي مصنع. قد تشمل المنتجات الموردة مخزونًا فائضًا أو عناصر غير مستخدمة. لا ندعي أي انتماء أو تأييد من قبل المصنعين الأصليين.