أُوكَازيُون
أُوكَازيُون
The Allen-Bradley 1756-OB16I, also cataloged as the 1756-OB16I Digital Output Module, operates as a dedicated hardware component for high-density discrete actuation within ControlLogix backplane platforms. The hardware establishes electronic switching across 12-24 VDC (10-30 VDC operating range) control loops at up to 2 A per point. Each of the 16 output channels features individual galvanic isolation up to 250 V continuous, preventing electrical noise transfer and ground loops across independent power source circuits.
| Parameter | Specification |
|---|---|
| Model | 1756-OB16I |
| Brand | Allen-Bradley / Rockwell Automation |
| Origin | USA |
| Weight | 0.40 lbs (0.18 kg) |
| Dimensions | ControlLogix Single-Slot Standard Module |
| Operating Temp | 0 to 60 deg C |
| Power Consumption | 3.6 W (Backplane: 350 mA at 5.1 VDC, 2.5 mA at 24 VDC) |
| Digital Outputs | 16 points |
| Output Type | 12-24 VDC (10-30 VDC range) Sink/Source |
| Isolation Voltage | 250 V continuous (channel-to-channel isolation) |
| Output Current Rating | 2 A per point |
| Terminal Block | Removable Terminal Block (36-Pin) |
The module communicates over the local ControlLogix backplane bus utilizing high-velocity CIP (Common Industrial Protocol) framing. Backplane bus communication velocity guarantees low deterministic latency during field output state updating. High-density I/O routing protocols ensure synchronous cyclic data transmission to the system controller, matching configured Requested Packet Interval (RPI) rates down to sub-millisecond thresholds. Firmware flash compatibility enables online updates through Studio 5000 Logix Designer without physically dismounting the chassis assembly.
Q: Can the 1756-OB16I module be removed or inserted under power (RIUP)?
A: Yes, the module supports Removal and Insertion Under Power (RIUP) within a powered ControlLogix chassis. However, field power connected to the 36-pin Removable Terminal Block (RTB) must be isolated prior to wiring block disconnection to prevent hazardous arc flash or unintended output state toggling.
Q: Does the 1756-OB16I support both sourcing and sinking field wiring configurations?
A: Yes, each isolated channel can be individually wired in either a sinking or sourcing topology, provided field voltage remains strictly within the 10-30 VDC operating window and individual channel isolation parameters are respected.

إرسال سريع من مخزوننا العالمي لتقليل وقت التوقف وضمان العمليات دون انقطاع.
جميع الأجزاء مصدرها شركات مصنعة ذات سمعة طيبة وتخضع لفحوصات جودة شاملة.
مخزون واسع النطاق من الأتمتة الصناعية والأجزاء المتوقفة، جاهزة للشحن الفوري.
يتم تغطية كل منتج - بما في ذلك المنتجات القديمة - بضمان لمدة 12 شهرًا وضمان إرجاع لمدة 30 يومًا.
جميع أسماء المنتجات والعلامات التجارية والشعارات المذكورة في هذا الموقع هي ملك لأصحابها. تُستخدم هذه الأسماء والعلامات التجارية لأغراض التعريف والمراجع فقط. نحن مورد مستقل لقطع غيار الأتمتة الصناعية. لسنا موزعًا أو تاجرًا أو ممثلاً معتمدًا لأي مصنع. قد تشمل المنتجات الموردة مخزونًا فائضًا أو عناصر غير مستخدمة. لا ندعي أي انتماء أو تأييد من قبل المصنعين الأصليين.