Configured for high-precision temperature measurement in ControlLogix chassis platforms, the Allen-Bradley 1756-IR6I (1756-IR6I Analog RTD Module) provides direct physical/electrical execution. The module digitizes resistance changes across 6 individually isolated RTD input channels to process thermal data from Platinum and Nickel sensors. Each channel provides complete channel-to-channel isolation, preventing ground potential differences and line-noise crosstalk between ungrounded or grounded sensor loops. The module interfaces directly with the local rack backplane system for power distribution, diagnostic parsing, and real-time sampling without requiring external isolation transmitters.
| Parameter | Specification |
|---|---|
| Model | 1756-IR6I |
| Brand | Allen-Bradley / Rockwell Automation |
| Origin | USA |
| Weight | 1.31 lbs (0.60 kg) |
| Dimensions | ControlLogix Single-Slot Standard Module |
| Operating Temp | 0 to 60 deg C |
| Power Consumption | 4.3 W Max (Backplane: 250 mA at 5 VDC, 125 mA at 24 VDC) |
| Number of Inputs | 6 points individually isolated |
| Compatible RTD Types | Platinum (100, 200, 500, 1000 ohm); Nickel (100, 120, 200, 500 ohm) |
| Resolution | 16 bits (7.7 to 60 mohm/bit across ranges) |
| Data Formats | Integer mode (2s complement), IEEE 32-bit floating point |
| Removable Terminal Blocks | 1756-TBNH, 1756-TBSH |
The module communicates over the local ControlLogix backplane bus utilizing high-velocity CIP (Common Industrial Protocol) framing. Backplane bus communication velocity guarantees low deterministic latency during real-time RTD channel sampling and data multicasting. High-density I/O routing protocols allow configuring Real-Time Sampling (RTS) and Requested Packet Interval (RPI) periods down to minimal scan thresholds. Firmware flash compatibility enables online channel reconfiguration, filter adjustments, and firmware synchronization via Studio 5000 Logix Designer software without interrupting backplane power.
Q: Can the 1756-IR6I module be removed or inserted under power (RIUP)?
A: Yes, the 1756-IR6I supports Removal and Insertion Under Power (RIUP) within a powered ControlLogix chassis. However, field wiring connected to the 20-pin Removable Terminal Block (RTB) should be safely disconnected or isolated to prevent signal transients during module insertion.
Q: What data formats are selectable for processing thermal readings on the 1756-IR6I?
A: The module supports Integer mode (left-justified 2s complement) and IEEE 32-bit floating-point mode. Floating-point mode enables integrated temperature linearization (Celsius or Fahrenheit), process/rate alarms, and digital filtering algorithms directly on the module.

إرسال سريع من مخزوننا العالمي لتقليل وقت التوقف وضمان العمليات دون انقطاع.
جميع الأجزاء مصدرها شركات مصنعة ذات سمعة طيبة وتخضع لفحوصات جودة شاملة.
مخزون واسع النطاق من الأتمتة الصناعية والأجزاء المتوقفة، جاهزة للشحن الفوري.
يتم تغطية كل منتج - بما في ذلك المنتجات القديمة - بضمان لمدة 12 شهرًا وضمان إرجاع لمدة 30 يومًا.
جميع أسماء المنتجات والعلامات التجارية والشعارات المذكورة في هذا الموقع هي ملك لأصحابها. تُستخدم هذه الأسماء والعلامات التجارية لأغراض التعريف والمراجع فقط. نحن مورد مستقل لقطع غيار الأتمتة الصناعية. لسنا موزعًا أو تاجرًا أو ممثلاً معتمدًا لأي مصنع. قد تشمل المنتجات الموردة مخزونًا فائضًا أو عناصر غير مستخدمة. لا ندعي أي انتماء أو تأييد من قبل المصنعين الأصليين.