Configured for non-volatile logic retention in SLC 500 processors, the Allen-Bradley 1747-M11 (1747-M11 Memory Module) provides direct physical/electrical execution of program and data table backup across supported controller platforms.
| Parameter | Specification |
|---|---|
| Brand | Allen-Bradley |
| Model | 1747-M11 |
| Origin | USA |
| Weight | 0.11 kg (0.25 lbs) |
| Dimensions | Direct socket processor mount footprint |
| Operating Temp | Standard SLC 500 rating (0 to 60 deg C operational) |
| Power Consumption | Passive onboard memory cell |
| Memory Capacity | 8 KB (1,000 instructions) |
| Backup Memory Type | Flash EEPROM |
| User Memory Support | Up to 32 KB backup capability |
| Program Scan Time | 0.9 ms base controller execution |
| I/O Scan Time | 0.225 ms |
| Processor Compatibility | SLC 5/03, SLC 5/04, SLC 5/05 (1747-L532, L541, L542, L543) |
| Incompatible Hardware | 1746-BAS, 1746-BAST modules |
The EEPROM memory module plugs directly into the processor socket, retaining controller logic and configuration tables independent of battery backing voltage. During controller boot execution, memory contents load directly onto the local bus, ensuring firmware flash compatibility and immediate data restoration. Backplane bus communication velocity remains uninterrupted, permitting rapid initialization of connected rack I/O modules and high-speed scanner links across deterministic industrial networks.
Q: Which hardware series revision limits apply when pairing the 1747-M11 with SLC 5/03, 5/04, or 5/05 controllers?
A: Series A 1747-M11 modules are restricted to SLC 5/03 Series A or B processors, whereas Series B 1747-M11 modules are required for SLC 5/03 (OS302), SLC 5/04 (OS401), and SLC 5/05 processors.
Q: Is an auxiliary adapter required when burning programs via an external socket programmer?
A: Yes, interfacing the 1747-M11 module with a user-supplied PROM programmer requires a 1747-M15 memory module socket adapter.
Q: Can the 1747-M11 be utilized alongside BASIC interface modules like the 1746-BAS?
A: No, the 1747-M11 is hardware incompatible with 1746-BAS and 1746-BAST specialty modules.
Always disconnect electrical power from the host SLC 500 rack prior to removing the processor module. Wear an ESD wrist strap grounded to the enclosure earth bar to prevent electrostatic discharge from damaging the integrated circuit pins.
Locate the memory module socket on the main processor circuit board. Orient the keyed lead headers on the 1747-M11 with the socket outline, taking care not to bend pins during insertion. Press firmly until the module is fully seated. Re-insert the controller into its designated chassis slot, lock the top and bottom chassis latches, and power up the system to configure EEPROM loading parameters in software.

إرسال سريع من مخزوننا العالمي لتقليل وقت التوقف وضمان العمليات دون انقطاع.
جميع الأجزاء مصدرها شركات مصنعة ذات سمعة طيبة وتخضع لفحوصات جودة شاملة.
مخزون واسع النطاق من الأتمتة الصناعية والأجزاء المتوقفة، جاهزة للشحن الفوري.
يتم تغطية كل منتج - بما في ذلك المنتجات القديمة - بضمان لمدة 12 شهرًا وضمان إرجاع لمدة 30 يومًا.
جميع أسماء المنتجات والعلامات التجارية والشعارات المذكورة في هذا الموقع هي ملك لأصحابها. تُستخدم هذه الأسماء والعلامات التجارية لأغراض التعريف والمراجع فقط. نحن مورد مستقل لقطع غيار الأتمتة الصناعية. لسنا موزعًا أو تاجرًا أو ممثلاً معتمدًا لأي مصنع. قد تشمل المنتجات الموردة مخزونًا فائضًا أو عناصر غير مستخدمة. لا ندعي أي انتماء أو تأييد من قبل المصنعين الأصليين.