أُوكَازيُون
أُوكَازيُون
Configured for displacement and shaft position monitoring in Allen-Bradley networks, the Allen-Bradley 1442-DR-5850 (1442-DR-5850 Proximity Probe Driver) provides direct physical/electrical execution.
| Parameter | Specification |
|---|---|
| Model | 1442-DR-5850 |
| Brand | Allen-Bradley |
| Origin | USA |
| Weight | Approximately 200 g (7.0 oz) |
| Dimensions | Standard 1442 Driver Chassis Footprint |
| Operating Temp | -20 to 65 deg C |
| Power Consumption | -15 mA Max (with 10 kohm load) |
| Target Calibration Material | AISI 4140 (JIS SCM440) Steel Flat Surface |
| Power Supply Voltage | -24 VDC |
| Maximum Output Voltage | -23 VDC |
| Fault Output Voltage | -0.6 VDC (Probe/Sensor OPEN or SHORT) |
| Output Noise | 20 mV peak-to-peak + power supply noise |
| Cable Diameter | 2.7 mm or 3.6 mm (0.11 in. or 0.14 in.) |
| Connector Diameter | 7.1 mm (0.28 in.) / Armored: 5.8 mm (0.23 in.) |
| System Cable Length | 5 m or 9 m (16.40 ft or 29.53 ft) Nominal |
| Driver Insulation Resistance | >= 100 Mohm @ 500 VDC (Terminals to Plate) |
| Isolation Voltage | 50 V Continuous (Tested at 500 VAC for 60 s) |
| Driver Wire Size | 0.75...1.25 mm2 (18...16 AWG) Shielded Copper |
| Terminal Block Type | Spring Lock Terminal |
The 1442-DR-5850 probe driver utilizes precise eddy-current probe scaling calibrated against AISI 4140 steel target surfaces to maintain high-accuracy mechanical displacement tracking. The system processes gap voltage validation across continuous dynamic signals, providing immediate fault detection by driving output levels to -0.6 VDC during probe open or short circuit conditions. High I/O density scaling and cross-talk suppression are sustained across 5 m or 9 m cable runs, maintaining low-noise voltage transmission back to monitoring hardware without signal distortion.
Q: What output voltage does the 1442-DR-5850 driver produce during a probe fault condition?
A: The driver outputs an abnormal fault voltage of -0.6 VDC whenever an open or short circuit condition is detected on the connected probe sensor.
Q: What wiring type and gauge are specified for connecting the 1442-DR-5850 driver terminals?
A: Connections require 0.75 to 1.25 mm2 (18 to 16 AWG) shielded stranded-copper wire rated at 90 deg C or higher, fitted to the onboard spring lock terminal block.

إرسال سريع من مخزوننا العالمي لتقليل وقت التوقف وضمان العمليات دون انقطاع.
جميع الأجزاء مصدرها شركات مصنعة ذات سمعة طيبة وتخضع لفحوصات جودة شاملة.
مخزون واسع النطاق من الأتمتة الصناعية والأجزاء المتوقفة، جاهزة للشحن الفوري.
يتم تغطية كل منتج - بما في ذلك المنتجات القديمة - بضمان لمدة 12 شهرًا وضمان إرجاع لمدة 30 يومًا.
جميع أسماء المنتجات والعلامات التجارية والشعارات المذكورة في هذا الموقع هي ملك لأصحابها. تُستخدم هذه الأسماء والعلامات التجارية لأغراض التعريف والمراجع فقط. نحن مورد مستقل لقطع غيار الأتمتة الصناعية. لسنا موزعًا أو تاجرًا أو ممثلاً معتمدًا لأي مصنع. قد تشمل المنتجات الموردة مخزونًا فائضًا أو عناصر غير مستخدمة. لا ندعي أي انتماء أو تأييد من قبل المصنعين الأصليين.