The ABB GJR2363200R0001, also cataloged as the ABB 87TS01E Gas Insulated Switchgear, operates as a dedicated hardware component for medium-voltage circuit interruption and distribution control within electrical grid networks.
| Parameter | Specification |
|---|---|
| Model | GJR2363200R0001 |
| Brand | ABB |
| Origin | Germany / Switzerland (Standard factory matrix) |
| Weight | 1.50kg |
| Dimensions | 600 mm (L) x 300 mm (W) x 1500 mm (H) |
| Operating Temp | -25 to +55 deg C |
| Power Consumption | Regulated by auxiliary tripping and spring charging circuits |
| Voltage Rating | Up to 36 kV |
| Rated Current | 1250 A |
| Short-Circuit Withstand Current | 25 kA for 3 seconds |
| Insulation Medium | SF6 (Sulfur Hexafluoride) gas |
| Protection Class | IP67 |
| Storage Temperature | -40 to +70 deg C |
| Relative Humidity | Up to 95% (non-condensing) |
| Installation Type | Floor Mounted |
The integration of the switchgear control architecture involves the transmission of interlocking and monitoring signals over high-velocity serial and parallel networks. Field telemetry paths and sensor arrays route critical status bits directly to sub-modules, which scale high I/O density points smoothly across the control backplane. System protection triggers require strict firmware flash compatibility matching across the connected protection relays to ensure deterministic circuit interruption speeds during short-circuit faults without signal latency or framing dropouts.
Q: What are the servicing procedures for the SF6 gas insulation system under continuous operation?
A: The SF6 gas insulation system is sealed within an IP67 enclosure to prevent leaking. Gas density must be verified using the integrated mechanical manometer or digital pressure transducers. Replenishment or evacuation processes must be handled utilizing specialized gas carts under complete circuit lockout.
Q: Can this unit handle high-vibration applications or ambient washdowns?
A: Yes. The IP67 rating protects the internal mechanical switching links and primary busbars from dust and high moisture environments. However, the external auxiliary wiring terminal blocks must be mounted inside an appropriately sealed, vibration-isolated marshaling enclosure.
Q: What defines the physical limit of the short-circuit withstand duration?
A: The switchgear is mechanically and thermally rated to withstand a peak short-circuit thermal impulse load of 25 kA for a maximum duration of 3 seconds. Protection relay coordination parameters must be programmed to trip the circuit breaker within this envelope to prevent busbar deformation.

إرسال سريع من مخزوننا العالمي لتقليل وقت التوقف وضمان العمليات دون انقطاع.
جميع الأجزاء مصدرها شركات مصنعة ذات سمعة طيبة وتخضع لفحوصات جودة شاملة.
مخزون واسع النطاق من الأتمتة الصناعية والأجزاء المتوقفة، جاهزة للشحن الفوري.
يتم تغطية كل منتج - بما في ذلك المنتجات القديمة - بضمان لمدة 12 شهرًا وضمان إرجاع لمدة 30 يومًا.
جميع أسماء المنتجات والعلامات التجارية والشعارات المذكورة في هذا الموقع هي ملك لأصحابها. تُستخدم هذه الأسماء والعلامات التجارية لأغراض التعريف والمراجع فقط. نحن مورد مستقل لقطع غيار الأتمتة الصناعية. لسنا موزعًا أو تاجرًا أو ممثلاً معتمدًا لأي مصنع. قد تشمل المنتجات الموردة مخزونًا فائضًا أو عناصر غير مستخدمة. لا ندعي أي انتماء أو تأييد من قبل المصنعين الأصليين.