أُوكَازيُون
أُوكَازيُون
| Color / Pattern |
|
| Power Source |
|
| Communication Protocols |
|
| Controller Design |
|
The Honeywell 2MLF‑AD16A, also cataloged as the 2MLF‑AD16A analog input module, serves as a 16‑channel voltage/current acquisition unit used to execute multi‑format analog signal conversion across MasterLogic‑200 platforms.
| Parameter | Specification |
|---|---|
| Model | 2MLF‑AD16A |
| Brand | Honeywell |
| Origin | MasterLogic‑200 Platform |
| Weight | 0.115 kg (shipping weight 2 kg) |
| Dimensions | Not specified |
| Operating Temp | 0 to 55 deg C |
| Storage Temp | −25 to +70 deg C |
| Operating Humidity | 5 to 95% RH, non‑condensing |
| Storage Humidity | 5 to 95% RH, non‑condensing |
| Environment | No corrosive gas or dust |
| Altitude | Below 2000 m |
| Contamination Level | Below 2 |
| Power Consumption | DC 5 V, 330 mA |
| Product Type | MasterLogic‑200 Analog Input Modules |
| Channels | 16 channels per module |
| Accuracy | ±0.2% @ 25 ±5 deg C; ±0.3% @ 0–55 deg C |
| Max Conversion Speed | 500 µs per channel |
| Isolation Method | Photo‑coupler isolation between input terminal and PLC power (no channel‑to‑channel isolation) |
| Terminal Block | 32‑point terminal |
| I/O Addressing | Fixed 64 points; variable 16 points |
As part of the MasterLogic‑200 architecture, the module aligns with Honeywell’s deterministic industrial‑network conventions. When deployed in systems using Profinet or similar deterministic Ethernet structures, the CPU maintains stable scan‑cycle timing and predictable analog refresh behavior. The module’s photo‑coupler isolation supports I/O density scaling across large multi‑rack configurations without introducing channel‑to‑channel interference.
Q: Can the 2MLF‑AD16A be hot‑swapped during operation? A: No. The module must be inserted or removed only when the MasterLogic‑200 rack is de‑energized.
Q: Does the 500 µs/channel conversion speed affect controller scan timing? A: Conversion speed determines how quickly each analog channel updates. Overall scan timing depends on the controller’s configured I/O strategy.
Q: How does the module handle channel isolation? A: Photo‑coupler isolation is provided between input terminals and PLC power. Channels themselves are not isolated from each other.

إرسال سريع من مخزوننا العالمي لتقليل وقت التوقف وضمان العمليات دون انقطاع.
جميع الأجزاء مصدرها شركات مصنعة ذات سمعة طيبة وتخضع لفحوصات جودة شاملة.
مخزون واسع النطاق من الأتمتة الصناعية والأجزاء المتوقفة، جاهزة للشحن الفوري.
يتم تغطية كل منتج - بما في ذلك المنتجات القديمة - بضمان لمدة 12 شهرًا وضمان إرجاع لمدة 30 يومًا.
جميع أسماء المنتجات والعلامات التجارية والشعارات المذكورة في هذا الموقع هي ملك لأصحابها. تُستخدم هذه الأسماء والعلامات التجارية لأغراض التعريف والمراجع فقط. نحن مورد مستقل لقطع غيار الأتمتة الصناعية. لسنا موزعًا أو تاجرًا أو ممثلاً معتمدًا لأي مصنع. قد تشمل المنتجات الموردة مخزونًا فائضًا أو عناصر غير مستخدمة. لا ندعي أي انتماء أو تأييد من قبل المصنعين الأصليين.