Configured for HART‑enabled analog acquisition in HC900/ControlEdge networks, the Honeywell 2MLF‑AC4H (2MLF‑AC4H HART analog input module) provides direct multi‑channel current/voltage measurement with integrated HART digital signal extraction across the backplane.
| Parameter | Specification |
|---|---|
| Model | 2MLF‑AC4H |
| Brand | Honeywell |
| Origin | HC900 / ControlEdge I/O Platform |
| Weight | Not specified |
| Dimensions | Not specified |
| Operating Temp | Not specified |
| Power Consumption | Not specified |
| Product Type | HART Analog Input Module |
| Channels | 4 analog input channels (HART‑enabled) |
| Signal Types | Current/voltage analog inputs with HART overlay |
| Data Handling | Analog value + HART digital variable extraction |
| Isolation Method | Photo‑coupler isolation between input terminal and PLC power (no channel‑to‑channel isolation) |
| Terminal Block | Not specified (standard MLF‑series terminal block assumed) |
| Conversion Speed | Not specified (MLF analog modules typically 250–500 µs/channel) |
| Absolute Max Input | Not specified |
The 2MLF‑AC4H is designed specifically for 4‑20 mA HART loop acquisition. The module extracts both the analog process variable and the HART digital secondary variables. Internal architecture uses photo‑coupler isolation between input terminals and PLC power, while HC900 I/O maintains channel‑to‑channel isolation at the system level to prevent cross‑loop interference. This ensures stable HART communication even under mixed analog/HART channel configurations.
Q: Can the 2MLF‑AC4H be hot‑swapped during operation? A: No. The module must be inserted or removed only when the controller rack is de‑energized.
Q: Does HART communication affect analog scan timing? A: Analog values update at standard module conversion speed. HART digital variables update at slower, protocol‑defined intervals without affecting analog refresh.
Q: Can each channel operate as non‑HART analog input? A: Yes. Channels can be configured for standard analog measurement when HART extraction is not required.

إرسال سريع من مخزوننا العالمي لتقليل وقت التوقف وضمان العمليات دون انقطاع.
جميع الأجزاء مصدرها شركات مصنعة ذات سمعة طيبة وتخضع لفحوصات جودة شاملة.
مخزون واسع النطاق من الأتمتة الصناعية والأجزاء المتوقفة، جاهزة للشحن الفوري.
يتم تغطية كل منتج - بما في ذلك المنتجات القديمة - بضمان لمدة 12 شهرًا وضمان إرجاع لمدة 30 يومًا.
جميع أسماء المنتجات والعلامات التجارية والشعارات المذكورة في هذا الموقع هي ملك لأصحابها. تُستخدم هذه الأسماء والعلامات التجارية لأغراض التعريف والمراجع فقط. نحن مورد مستقل لقطع غيار الأتمتة الصناعية. لسنا موزعًا أو تاجرًا أو ممثلاً معتمدًا لأي مصنع. قد تشمل المنتجات الموردة مخزونًا فائضًا أو عناصر غير مستخدمة. لا ندعي أي انتماء أو تأييد من قبل المصنعين الأصليين.