The Yokogawa ALF111-S00, also cataloged as the ALF111 FOUNDATION Fieldbus Communication Module, operates as a dedicated hardware component for Link Active Scheduler (LAS) management and H1 fieldbus segment distribution within distributed control system (DCS) platforms.
The ALF111 series utilizes explicit engineering suffixes to define hardware builds and hardware style revisions. Below is the technical breakdown for the ALF111-S00 configuration:
| Parameter | Specification |
|---|---|
| Model | ALF111-S00 |
| Brand | Yokogawa |
| Origin | Japan |
| Weight | 0.3 kg (0.66 lbs) |
| Dimensions | 127 mm x 25 mm x 127 mm (5.0" x 1.0" x 5.0") |
| Operating Temp | -40 to +70 deg C |
| Power Supply Voltage | 24 VDC |
| Power Consumption | 1.5 W maximum rated draw |
| Product Type | Fieldbus Communication Modules |
| Physical Interface | 2-wire FOUNDATION Fieldbus H1 |
| Transmission Speed | 31.25 Kbps fixed transmission rate |
| Dielectric Strength | Withstanding voltage of 1500 VAC per minute from field to system |
| Bus Connection | Pressure clamp terminals on a removable terminal block |
| Segment Termination | Built-in software-selectable or hardware terminators |
| Device Capacity | Maximum 32 fieldbus devices per segment loop |
| Channel Capacity | Supports up to 48 control I/O points per segment loop |
| Redundancy Support | Dual-redundant configuration pairing compatible |
| Target Control Units | Mounts on AFV10, AFV30, AFV40, AFF50, and ESB / ER bus node units |
Q: What are the consequences if a module running as the active Link Active Scheduler (LAS) fails on the H1 loop?
A: If the primary ALF111-S00 fails in a non-redundant layout, a configured backup LAS device located directly on the field network segment detects the loss of the scheduling token and automatically assumes control of the macrocycle execution timing to prevent loss of process data.
Q: Can the ALF111-S00 directly power the 32 fieldbus transmitters connected to its H1 segment loop?
A: No. The communication module does not inject operating power into the signal lines. An external, dedicated fieldbus power supply paired with an impedance-matching fieldbus power conditioner must be installed on the H1 network segment to drive connected transmitters and valves.

Quick dispatch from our global inventory to reduce downtime and ensure uninterrupted operations.
All parts are sourced from reputable manufacturers and undergo thorough quality checks.
Extensive stock of industrial automation and discontinued parts, ready for immediate shipment.
Every product — including obsolete items — is covered by a 12-month warranty and 30-day return guarantee.
All product names, trademarks, brands, and logos mentioned on this website are the property of their respective owners.These names and trademarks are used for identification and reference purposes only.We are an independent supplier of industrial automation spare parts.We are not an authorized distributor, dealer, or representative of any manufacturer.Products supplied may include surplus inventory or unused items.We do not claim any affiliation with or endorsement by the original manufacturers.