Sale
| Color / Pattern |
|
| Power Source |
|
| Controller Design |
|
The Honeywell TK-OAV081, also cataloged as the OAV081 analog output module, operates as a dedicated hardware component for current and voltage signal generation within Honeywell process control systems.
| Parameter | Specification |
|---|---|
| Model | TK-OAV081 |
| Brand | Honeywell |
| Origin | Honeywell process control platforms |
| Weight | 0.5 kg (Shipping weight: 2 kg) |
| Dimensions | Not specified in provided data |
| Operating Temp | Standard industrial ambient range |
| Power Consumption | 6.9 W max |
| Core Function | 8-point analog output (current/voltage) |
| Voltage Output Range | ±10.4 V |
| Current Output Range | 0 to 21 mA |
| Resolution | 320 µV per count (Voltage), 650 nA per count (Current) |
| Accuracy | Better than 0.05% at 25 deg C |
| Isolation | 2550 VDC user-to-system, tested 1 s |
| Protection | Overvoltage protection, short-circuit current limiting |
| Update Rate | 25 ms for all channels |
| Settling Time | <2 ms to 95% final value |
| Connection | TC-TBNH, 20-position terminal block |
The TK-OAV081 supports integration with Honeywell environments utilizing 4-20 mA HART loop protocol, enabling simultaneous analog signal transmission and diagnostic communication. Channel-to-channel isolation ensures that voltage and current outputs remain independent, minimizing interference across the eight channels. Cold junction compensation (CJC) is applied for stability in varying ambient conditions.
Q: Can the TK-OAV081 drive high-resistance loads? A: Yes, voltage outputs can drive >2000 Ω loads, while current outputs support up to 750 Ω.
Q: What is the module’s behavior under short-circuit conditions? A: Outputs are electronically limited to 21 mA or less, preventing damage during open or short circuit events.
Q: How does temperature drift affect accuracy? A: Typical offset drift is 50 µV/deg C (voltage) and 100 nA/deg C (current), with gain drift limited to 25 ppm/deg C (voltage) and 50 ppm/deg C (current).
Mount the module securely in the designated chassis slot.
Connect TC-TBNH 20-position terminal block with proper torque to avoid loose contacts.
Ground shielding at a single point to reduce RFI susceptibility.
Verify load resistance compatibility before energizing outputs.
Maintain clearance for airflow to dissipate 6.9 W maximum heat.

Quick dispatch from our global inventory to reduce downtime and ensure uninterrupted operations.
All parts are sourced from reputable manufacturers and undergo thorough quality checks.
Extensive stock of industrial automation and discontinued parts, ready for immediate shipment.
Every product — including obsolete items — is covered by a 12-month warranty and 30-day return guarantee.
All product names, trademarks, brands, and logos mentioned on this website are the property of their respective owners.These names and trademarks are used for identification and reference purposes only.We are an independent supplier of industrial automation spare parts.We are not an authorized distributor, dealer, or representative of any manufacturer.Products supplied may include surplus inventory or unused items.We do not claim any affiliation with or endorsement by the original manufacturers.