The GE IS200EACFG2A Exciter AC Feedback Board operates as a dedicated input/output terminal board engineered to execute phase-voltage and magnetic flux measurements within EX2100 Excitation Control System platforms.
| Parameter | Specification |
|---|---|
| Model | IS200EACFG2A (Base Model: EACF) |
| Brand | General Electric (GE) |
| Series | EX2100 Excitation Control |
| Product Type | Input/Output Terminal Board |
| Board Version | G2 (Second Version) |
| Shipping Weight | 1.5 lb |
| Exciter Voltage Measurement | Up to 1000 VRMS |
| Monitored Inputs | Power Potential Transformer (PPT) AC signals |
| Transformer Array | 4 onboard phase-voltage transformers (T1, T2, T3, T4) |
| Sensor Interface Connection | Terminal Block 4 (TB4) for Flux/Air Core Coils |
The EACF board acts as the primary analog interface layer for high-voltage AC feedback streams within the EX2100 excitation framework. The G2 hardware version routes three-phase input voltages from the Power Potential Transformer (PPT) through an array of four galvanic isolation transformers to step down high-potential waveforms before digitization. All voltage scaling coefficients, flux integration calculations, and phase-angle synchronization routines are bound to the specific firmware flash revision compiled on the master control processor, ensuring deterministic loop tracking and preventing harmonic measurement distortion across the internal system bus.
The board layout utilizes explicit physical zones for its isolation components and sensor interfaces. The four onboard transformers are arranged sequentially to align with signal paths:
For magnetic flux tracking, Flux/Air Core Coils link directly to Terminal Block 4 (TB4) using a strict terminal allocation scheme:
Q: What is the maximum AC potential that the IS200EACFG2A can directly measure? A: The G2 version of this module is engineered to support an exciter voltage measurement range up to 1000 VRMS across its three-phase transformer inputs.
Q: How does the configuration of the G2 version differ from other EACF board iterations? A: Version G2 is defined by its onboard configuration of four phase-voltage transformers arranged to process a single three-phase AC input voltage step-down alongside dedicated air-core coil interfaces.
Q: What function do the air-core coils wired to terminal TB4 perform? A: These coils interface with the board to feed raw magnetic flux signals from the generator/exciter housing into the EX2100 control loops for internal calculation algorithms.

Quick dispatch from our global inventory to reduce downtime and ensure uninterrupted operations.
All parts are sourced from reputable manufacturers and undergo thorough quality checks.
Extensive stock of industrial automation and discontinued parts, ready for immediate shipment.
Every product — including obsolete items — is covered by a 12-month warranty and 30-day return guarantee.
All product names, trademarks, brands, and logos mentioned on this website are the property of their respective owners.These names and trademarks are used for identification and reference purposes only.We are an independent supplier of industrial automation spare parts.We are not an authorized distributor, dealer, or representative of any manufacturer.Products supplied may include surplus inventory or unused items.We do not claim any affiliation with or endorsement by the original manufacturers.