Sale
The GE 369-HI-R-M-0-2-0-0, also cataloged as the 369-HI-R-M-0-2-0-0 I/O Relay Module, operates as a dedicated hardware component for signal expansion and motor protection trip logic within GE Multilin 369 Motor Management Relay systems.
| Option Position | Ordering Code | Technical Feature |
|---|---|---|
| Series Base | 369 | Multilin Motor Management Protection System |
| Control Power | HI | High Voltage Range (50-300 VDC / 60-265 VAC) |
| Conformal Coating | R | Harsh Environment Conformal Coating Option |
| Modbus Option | M | Modbus RTU Protocol Communication Enablement |
| RTD Option | 0 | None (Standard Base Configuration) |
| Current Inputs | 2 | 1 A / 5 A Phase CT Inputs |
| Analog I/O | 0 | Standard Base I/O Configuration |
| Conformal Coating | 0 | Standard Internal PCB Assembly Designation |
| Parameter | Specification |
|---|---|
| Model | 369-HI-R-M-0-2-0-0 |
| Brand | GE Multilin |
| Product Type | I/O Relay Modules |
| Digital Inputs | 8 channels, wet/dry contact configurable |
| Input Voltage Range | 24-125 VDC / 24-240 VAC |
| Input Impedance | 3.3 kΩ at 125 VDC typical |
| Digital Outputs (Relay) | 4 channels, Form C (SPDT), 8 A at 250 VAC / 30 VDC |
| Analog Outputs | 2 channels, 4-20 mA isolated (±0.5% full scale accuracy) |
| Isolation Voltage | 2500 VAC input-to-output, output-to-ground |
| Power Consumption | 5 W maximum from base unit |
| Operating Temp | -40 to 70 deg C |
| Dimensions | 180 x 45 x 150 mm |
| Weight | 0.6 kg |
| Origin | USA |
Q: What is the maximum contact switching capacity for the digital relay outputs on the 369-HI-R-M-0-2-0-0?
A: The four Form C electromechanical output relays are rated for 8 A at 250 VAC or 30 VDC resistive loads, making them suitable for direct contactor switching.
Q: How does the module handle signal conditioning for different field digital input voltages?
A: The digital input channels incorporate internal high-impedance (3.3 kΩ typical) wet/dry contact sensing circuits that accept wide-range inputs from 24 to 240 VAC or 24 to 125 VDC without external drop resistors.
Q: Can the 369-HI-R-M-0-2-0-0 expansion card be hot-swapped while the Multilin 369 base unit is powered?
A: No, the control power to the main 369 relay chassis must be completely isolated and de-energized prior to inserting or removing the expansion card to prevent edge-connector damage.

Quick dispatch from our global inventory to reduce downtime and ensure uninterrupted operations.
All parts are sourced from reputable manufacturers and undergo thorough quality checks.
Extensive stock of industrial automation and discontinued parts, ready for immediate shipment.
Every product — including obsolete items — is covered by a 12-month warranty and 30-day return guarantee.
All product names, trademarks, brands, and logos mentioned on this website are the property of their respective owners.These names and trademarks are used for identification and reference purposes only.We are an independent supplier of industrial automation spare parts.We are not an authorized distributor, dealer, or representative of any manufacturer.Products supplied may include surplus inventory or unused items.We do not claim any affiliation with or endorsement by the original manufacturers.