Sale
Configured for PWM‑based control power generation and contactor drive functions in EX2000 excitation networks, the GE IS200PSCDG1ADB (IS200PSCDG1ADB power supply / contactor driver board) provides regulated low‑voltage distribution, isolated auxiliary supplies, and DC link‑derived contactor control power for LDCC, TCCB, gate driver, and SHVI/SHVM subsystems.
| Parameter | Specification |
|---|---|
| Model | IS200PSCDG1ADB |
| Brand | General Electric |
| Origin | United States |
| Weight | 2 lbs |
| Dimensions | 16.2 cm high x 8.6 cm |
| Operating Temp | 0 to 70 deg C |
| Storage Temp | -40 to 80 deg C |
| Power Consumption | Not specified |
| Product Type | PWM Power Supply / Contactor Driver Board |
| Series | EX2000 |
| Microprocessor | Intel Celeron 300 MHz |
| Memory | 32 MB DRAM |
| Operating System | QNX |
| Programming | Boolean |
| Ethernet Interface | 10BaseT / 100BaseTX |
| Voltage Range | 14 to 32 V dc |
| Max Load Current | 125 V dc |
| Max Lead Resistance | 15 ohm |
| Technology | Surface mount |
| Core Function | DC link‑derived control power generation, isolated auxiliary supplies, contactor coil drive |
| Manual | GEI‑100241 |
As an EX2000 subsystem board, PSCD aligns with deterministic backplane timing used for excitation control sequencing. The board’s processor executes Boolean logic blocks stored in firmware flash, defining supply enable states, contactor permissive logic, and distribution timing for ±24 V, ±15 V, +5 V, and isolated 70 V dc outputs. Compatibility requires matched firmware revisions across LDCC and TCCB modules; mismatches may inhibit relay K1/K86 control or disrupt auxiliary supply availability. Ethernet communication through the secondary 10BaseT/100BaseTX interface follows deterministic update cycles for diagnostic retrieval.
Q: Can the IS200PSCDG1ADB be replaced while the exciter remains energized? A: No. The board must be installed or removed only when the EX2000 system is de‑energized to avoid undefined supply states and contactor coil activation.
Q: How does the board manage isolated auxiliary supplies? A: High‑frequency transformers generate isolated 70 V dc and SHVI/SHVM supplies. These outputs are filtered and routed through dedicated connectors for downstream modules.
Q: What determines the enable state of the MDA contactor? A: An optically coupled signal, logically parallel to relay K1, controls the MDA contactor. Relay K86 provides the permissive path and drops out immediately during emergency stop conditions.

Quick dispatch from our global inventory to reduce downtime and ensure uninterrupted operations.
All parts are sourced from reputable manufacturers and undergo thorough quality checks.
Extensive stock of industrial automation and discontinued parts, ready for immediate shipment.
Every product — including obsolete items — is covered by a 12-month warranty and 30-day return guarantee.
All product names, trademarks, brands, and logos mentioned on this website are the property of their respective owners.These names and trademarks are used for identification and reference purposes only.We are an independent supplier of industrial automation spare parts.We are not an authorized distributor, dealer, or representative of any manufacturer.Products supplied may include surplus inventory or unused items.We do not claim any affiliation with or endorsement by the original manufacturers.