Sale
| Color / Pattern |
|
| Power Source |
|
| Controller Design |
|
Configured for DC feedback acquisition at the SCR bridge within the EX2100 excitation system, the GE IS200EDCFG1A (IS200EDCFG1A Exciter DC Feedback Board) provides direct measurement of field current and field voltage and transfers these signals to the EISB module through a fiber‑optic link.
The input documentation does not define any suffix segmentation or variant matrix for IS200EDCFG1A. The model is treated as a single, fixed hardware configuration within the EX2100 platform.
| Parameter | Specification |
|---|---|
| Model | IS200EDCFG1A |
| Brand | GE |
| Origin | USA |
| Weight | Not specified |
| Dimensions | Not specified |
| Operating Temp | -30 to 65 deg C |
| Power Consumption | Not specified (powered through EX2100 cabinet interface) |
| Series | EX2100 |
| Product Type | Exciter DC Feedback Board |
| Field Voltage Input | SCR bridge DC voltage sensing |
| Field Current Input | SCR bridge DC current sensing |
| Signal Transport | Dual‑fiber optical link to EISB board |
| Isolation Method | Fiber‑optic galvanic isolation |
| Noise Immunity | High immunity due to optical transmission |
| Manual Reference | GEI‑100464A |
Within the EX2100 architecture, the IS200EDCFG1A aligns with deterministic controller timing for DC feedback sampling. The fiber‑optic link ensures stable propagation delay independent of electrical noise at the SCR bridge. This behavior supports I/O density scaling across EMIO and EISB modules and maintains compatibility with firmware flash updates applied to upstream controllers. The optical isolation prevents backplane ground loops and preserves deterministic behavior in Profinet / EtherNet/IP deterministic networks when EX2100 systems are integrated with plant‑wide PLC/DCS networks.
Q: Can the IS200EDCFG1A be replaced while the excitation panel is energized? A: No. The board interfaces directly with SCR bridge feedback circuits and must only be handled when the cabinet is fully de‑energized.
Q: Does the fiber‑optic link require calibration after board replacement? A: No calibration is required. The optical link is point‑to‑point and automatically aligns with the EISB receiver once connected.
Q: Are there any firmware dependencies for this board? A: The board contains no user‑upgradeable firmware. Compatibility is determined by the EISB and controller firmware baseline configured for the EX2100 system.

Quick dispatch from our global inventory to reduce downtime and ensure uninterrupted operations.
All parts are sourced from reputable manufacturers and undergo thorough quality checks.
Extensive stock of industrial automation and discontinued parts, ready for immediate shipment.
Every product — including obsolete items — is covered by a 12-month warranty and 30-day return guarantee.
All product names, trademarks, brands, and logos mentioned on this website are the property of their respective owners.These names and trademarks are used for identification and reference purposes only.We are an independent supplier of industrial automation spare parts.We are not an authorized distributor, dealer, or representative of any manufacturer.Products supplied may include surplus inventory or unused items.We do not claim any affiliation with or endorsement by the original manufacturers.