{"product_id":"yokogawa-f3cx04-0n-temperature-monitoring-module","title":"Yokogawa F3CX04-0N Temperature Monitoring Module","description":"\u003ch2\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eYokogawa F3CX04-0N \u003c\/strong\u003eTemperature Monitoring Module is a single‑slot FA‑M3 PLC module designed for multi‑channel thermal data acquisition. It supports universal inputs, enabling flexible sensor integration for industrial automation and process safety monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Yokogawa Electric Corporation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e F3CX04-0N\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType:\u003c\/strong\u003e Temperature Monitoring Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eChannels:\u003c\/strong\u003e 4 independent universal input channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSupported Sensors:\u003c\/strong\u003e Thermocouples (15 types), RTDs (9 types), DC voltage (mV\/V)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e −200 °C to +1370 °C (depending on sensor type)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.1% of full scale\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e 0.1 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSampling Period:\u003c\/strong\u003e 200 ms (4 channels), 100 ms (2 channels)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e Photocoupler \u0026amp; transformer isolation, withstand 1500 V AC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAlarm Functions:\u003c\/strong\u003e High\/low temperature alarms with ON delay\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBurnout Detection:\u003c\/strong\u003e Configurable (upscale\/downscale\/none)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 440 mA at 5 V DC (~4 W)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 28.9 × 100 × 106.1 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.2 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 °C to +55 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eUniversal Input:\u003c\/strong\u003e Each channel configurable for thermocouple, RTD, or DC voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh Precision:\u003c\/strong\u003e ±0.1% accuracy with 0.1 °C resolution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFast Sampling:\u003c\/strong\u003e 200 ms for 4 channels, ensuring real‑time monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAlarm Capability:\u003c\/strong\u003e Built‑in high\/low temperature alarms with relay outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBurnout Detection:\u003c\/strong\u003e Detects sensor failures with configurable response\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData Retention:\u003c\/strong\u003e Stores input conditions internally, no need for reset at startup\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial Reliability:\u003c\/strong\u003e Compact design with robust isolation for harsh environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":47656108720318,"sku":"F3CX04-0N","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-15_17-42-55_900fa75d-3573-4074-b80c-65401a218244.png?v=1781518022","url":"https:\/\/www.autooiltech.com\/products\/yokogawa-f3cx04-0n-temperature-monitoring-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}