{"product_id":"yokogawa-cp471-50-processor-module","title":"Yokogawa CP471-50 Processor Module","description":"\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-405\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eCP471-50\u003c\/strong\u003e\u003cspan class=\"citation-405 citation-end-405\"\u003e\u003cspan\u003e \u003c\/span\u003eis a state-of-the-art processor module designed for Yokogawa’s CENTUM VP Field Control Stations (FCS), specifically optimized for the AFV30, AFV40, A2FV50, and A2FV70 series Field Control Units.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eAs a core controller, it provides significantly higher processing speeds and larger memory capacity compared to legacy CP461 units, ensuring rapid execution of complex regulatory and sequence control logic. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-404\"\u003e\u003c\/span\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003cspan class=\"citation-404 citation-end-404\"\u003e: Main CPU for Field Control Units (AFV30\/AFV40\/A2FV50\/A2FV70)\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-403\"\u003e\u003c\/span\u003e\u003cstrong\u003eControl Network\u003c\/strong\u003e\u003cspan class=\"citation-403 citation-end-403\"\u003e: Dual-redundant Vnet\/IP high-speed interface\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuffix Code\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Basic type with no explosion protection)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-402\"\u003e\u003c\/span\u003e\u003cstrong\u003eLogic Performance\u003c\/strong\u003e\u003cspan class=\"citation-402 citation-end-402\"\u003e: Enhanced 32-bit RISC processing (Supports R6.05+ software)\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-401\"\u003e\u003c\/span\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003cspan class=\"citation-401 citation-end-401\"\u003e: Supports \"Pair-and-Spare\" dual-redundant architecture\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Tolerance\u003c\/strong\u003e: Integrated ECC (Error Correcting Code) memory protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent Logging\u003c\/strong\u003e: Onboard buffer stores up to 10,000 sequence-of-events (SOE) entries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Resolution\u003c\/strong\u003e: 1 ms time-stamp resolution for forensic analysis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Protection\u003c\/strong\u003e: Built-in replaceable battery (S9450FE) for memory retention\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-400\"\u003e\u003c\/span\u003e\u003cstrong\u003ePhysical Weight\u003c\/strong\u003e\u003cspan class=\"citation-400 citation-end-400\"\u003e: 0.7 Kg (Net) \/ 2.0 Kg (Shipping weight typical)\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommon FAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the CP471-50 replace an existing CP461 module?\u003c\/strong\u003eYes, a pair of CP461 modules can be online-replaced with a pair of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP471-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules, provided your system is running CENTUM VP R6.05 or later and uses an EC401 bus coupler with style code S3 or higher. Note that mixing one CP461 and one\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP471-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein a single redundant pair is prohibited.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the -50 and -51 versions?\u003c\/strong\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP471-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the basic standard type, while the -51 version typically includes the ISA Standard G3 option, which adds an extra layer of conformal coating to protect the internal circuitry against corrosive gases\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":46394667663550,"sku":"CP471-50","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/yokogawa-aap135-s00-s2-pulse-input-module-cymztlvujog_fe110023-4de5-4fc1-8b74-4f0f24bfff62.png?v=1776329475","url":"https:\/\/www.autooiltech.com\/products\/yokogawa-cp471-50-processor-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}