{"product_id":"yokogawa-anb10d-427-cu2n-centum-vp-node-units","title":"Yokogawa ANB10D-427\/CU2N CENTUM VP Node Units","description":"\u003cp\u003eConfigured for field I\/O expansion in CENTUM VP control platforms, the \u003cstrong\u003eYokogawa ANB10D-427\/CU2N\u003c\/strong\u003e (\u003cstrong\u003eANB10D-427\u003c\/strong\u003e Node Unit) provides direct physical\/electrical execution of high-speed bus communication and field device integration.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eANB10D\u003c\/td\u003e\n\u003ctd\u003eNode unit for Dual-Redundant ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e220 - 240 V AC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 option, no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/CU2N\u003c\/td\u003e\n\u003ctd\u003eConnector unit for ESB Bus [S9562FA (2 pieces)]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANB10D-427\/CU2N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10.0 kg (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e19-inch rack mount profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem dependent (220 - 240 V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e The unit maintains signal path integrity for HART-enabled instrumentation, ensuring that device diagnostic data is processed and relayed to the DCS asset management host without attenuation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e The ESB bus architecture supports the deterministic exchange of digital fieldbus data, allowing for seamless integration of smart instrumentation into the process control network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e Internal circuitry provides galvanic isolation between the ESB bus interface and field-connected I\/O modules, protecting the control network from transients and common-mode noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e The unit utilizes precision thermal sensing on the terminal boards to execute accurate CJC calculations for thermocouple signals, maintaining measurement precision across the node.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ISA Standard G3 option require special environmental considerations?\u003c\/p\u003e\n\u003cp\u003eA: The G3 option provides enhanced protection against corrosive atmospheres. Ensure that air filtration and cabinet sealing are maintained in accordance with site specifications to maximize the service life of the conformal coating.\u003c\/p\u003e\n\u003cp\u003eQ: Is the \/NDEL option code mandatory for this unit?\u003c\/p\u003e\n\u003cp\u003eA: Yes. It is mandatory to specify the Option Code \/NDEL to enable the node connection within the system database configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the node unit into a standard 19-inch equipment rack. Use all required mounting fasteners to ensure structural stability and mitigate the effects of mechanical vibration on bus connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Bond the node chassis to the cabinet protective earth (PE) bus using a dedicated low-impedance ground cable. A solid ground reference is mandatory for high-speed ESB bus electromagnetic compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect the 220 - 240 V AC power supply to the redundant input terminals, ensuring proper phasing. Separate ESB bus communication cables from high-voltage AC lines to prevent induced interference. Verify the correct seating of S9562FA connector units.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48160590823614,"sku":"ANB10D-427\/CU2N","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-09_16-36-30_fba03d52-e6c5-4943-a77b-062686f9c351.png?v=1784007612","url":"https:\/\/www.autooiltech.com\/products\/yokogawa-anb10d-427-cu2n-centum-vp-node-units","provider":"AutoOilTech Limited","version":"1.0","type":"link"}