{"product_id":"yokogawa-anb10d-425-cu2t-ndel-bus-node-unit","title":"Yokogawa ANB10D-425\/CU2T\/NDEL Bus Node Unit","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ANB10D-425\/CU2T\/NDEL\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eANB10D-425\/CU2T\/NDEL\u003c\/strong\u003e ESB Bus Node Unit, operates as a dedicated hardware component for dual-redundant bus communication and node expansion within Yokogawa industrial automation platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Segment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Designation\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription \u0026amp; Configuration\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eANB10D\u003c\/td\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eNode Unit for Dual-Redundant ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-4\u003c\/td\u003e\n\u003ctd\u003ePower Supply Suffix\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003ePower Input Suffix\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC power supply input rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eEnvironmental Rating\u003c\/td\u003e\n\u003ctd\u003eBasic type with no explosion protection classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/CU2T\u003c\/td\u003e\n\u003ctd\u003eOption Code\u003c\/td\u003e\n\u003ctd\u003eConnector unit with terminator for ESB Bus (includes 2 pieces of part No. S9564FA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/NDEL\u003c\/td\u003e\n\u003ctd\u003eOption Code\u003c\/td\u003e\n\u003ctd\u003eSoftware License for Node Expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANB10D-425\/CU2T\/NDEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGlobal Manufacturing Facility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10 kg (Shipping weight: 10 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Yokogawa node unit rack form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial cabinet range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDual-redundant AC supply load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC dual-redundant input configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eDual-redundant ESB Bus with termination and node expansion support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe node unit maintains rigorous signal integrity across multi-loop instrumentation channels through integrated electrical isolation and robust shielding architectures. FOUNDATION Fieldbus and Profibus PA connectivity protocols are supported across the overarching DCS framework, while cold junction compensation (CJC) maintains thermal stability for termination blocks. 4-20 mA HART loop protocol compatibility ensures transparent transmission of diagnostic and process variables from field transmitters without signal attenuation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the specific function of the \/CU2T option code on this node unit?\u003c\/p\u003e\n\u003cp\u003eA: The \/CU2T suffix designates an ESB bus connector unit equipped with a terminator, including two pieces of part number S9564FA to ensure proper line impedance.\u003c\/p\u003e\n\u003cp\u003eQ: Does this unit feature a dual-redundant power configuration?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The -4 suffix and hardware architecture incorporate a dual-redundant 220-240 V AC power supply setup to ensure uninterrupted operation during power faults.\u003c\/p\u003e\n\u003cp\u003eQ: Can this ESB bus node unit be replaced while the system rack is energized?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swap procedures must comply with specific Yokogawa safety guidelines, requiring proper bus isolation and redundant power shutdown to prevent network disruptions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the node unit securely into the control cabinet using approved mechanical fastening and grounding practices to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003eVerify that all 220-240 V AC power feeds are isolated and locked out prior to connecting wiring to the terminal blocks.\u003c\/li\u003e\n\u003cli\u003eConnect the dual-redundant ESB bus communication cables and the \/CU2T connector unit with terminators securely, ensuring correct physical placement.\u003c\/li\u003e\n\u003cli\u003eCheck power status indicators and verify bus synchronization using engineering software before re-energizing the system.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48182027944126,"sku":"ANB10D-425\/CU2T\/NDEL","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-22_10-02-29_3f0a0c29-1ec2-4678-aeb2-618c925473fb.png?v=1784692617","url":"https:\/\/www.autooiltech.com\/products\/yokogawa-anb10d-425-cu2t-ndel-bus-node-unit","provider":"AutoOilTech Limited","version":"1.0","type":"link"}