{"product_id":"yokogawa-anb10d-415-cu2n-ndel-node-interface","title":"Yokogawa ANB10D-415\/CU2N\/NDEL Node Interface","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ANB10D-415\/CU2N\/NDEL(BASE PLATE)\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eANB10D-415\u003c\/strong\u003e Node Interface, operates as a dedicated hardware component for ESB bus I\/O signal management within CENTUM VP platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eANB10D\u003c\/td\u003e\n\u003ctd\u003eBase ESB Bus Node Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e100 - 120 V AC power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eBasic type (no explosion protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/CU2N\u003c\/td\u003e\n\u003ctd\u003eConnector Unit (Non-terminated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/NDEL\u003c\/td\u003e\n\u003ctd\u003ePre-installed Node Expansion License\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANB10D-415\/CU2N\/NDEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSingapore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 19-inch rack format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial ambient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem-dependent load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Function\u003c\/td\u003e\n\u003ctd\u003eDual-redundant ESB bus node\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Connectivity\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART Loop Protocol\u003c\/strong\u003e: The unit maintains signal transparency for HART-enabled instrumentation, facilitating the passage of primary process variables and secondary diagnostic data from field devices to the host controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA Connectivity\u003c\/strong\u003e: The architecture supports high-speed, deterministic data throughput, allowing the seamless integration of Fieldbus and Profibus PA segments through the internal backplane without inducing communication jitter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-Channel Isolation\u003c\/strong\u003e: High-density isolation circuitry on the backplane prevents potential signal coupling or cross-talk between discrete and analog channels, ensuring the integrity of field signals during transit to the Field Control Unit (FCU).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Junction Compensation (CJC)\u003c\/strong\u003e: The node supports I\/O modules utilizing CJC, with a mechanical design that ensures the required thermal stability for accurate cold junction reference measurements in thermocouple-based temperature monitoring applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ANB10D-415 support redundant communication paths?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The ANB10D series is designed for dual-redundant ESB bus communication, providing high-availability data transport between the remote I\/O chassis and the Field Control Unit.\u003c\/p\u003e\n\u003cp\u003eQ: Is the \/NDEL license required for initial system commissioning?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The pre-installed \/NDEL license is necessary for the CENTUM VP software to recognize and integrate the node interface into the existing system database.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting\u003c\/strong\u003e: Install the node interface into a standard 19-inch cabinet rack using appropriate M5 hardware. Ensure the chassis is bonded to the cabinet earth ground to prevent electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESB Bus Cabling\u003c\/strong\u003e: Use the \/CU2N connector interface for ESB bus input and output. Ensure that all cables are routed through segregated signal ducts to prevent inductive noise pickup from high-voltage power lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connectivity\u003c\/strong\u003e: Connect the dual power inputs to independent 100–120 VAC circuits to ensure operational redundancy. Verify the input voltage matches the rated specification before energizing the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: Connect the frame ground terminal to a low-impedance plant ground bus. Proper grounding is critical for maintaining the specified deterministic timing performance of the ESB bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidation\u003c\/strong\u003e: Confirm link synchronization between the node and the FCU via the CENTUM VP system management terminal. Perform a visual inspection of the front panel status LEDs to ensure both power channels are active and the ESB bus is healthy.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48177212653758,"sku":"ANB10D-415\/CU2N\/NDEL(BASE PLATE)","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-10_10-11-23_40b5e1f8-7ab7-4154-b851-fc28f732e027.png?v=1784513631","url":"https:\/\/www.autooiltech.com\/products\/yokogawa-anb10d-415-cu2n-ndel-node-interface","provider":"AutoOilTech Limited","version":"1.0","type":"link"}