{"product_id":"yokogawa-anb10d-410-ndel-node-unit","title":"Yokogawa ANB10D-410\/NDEL Node Unit","description":"\u003cp\u003eConfigured for distributed I\/O management in Fieldbus Control System (FCS) architectures, the \u003cstrong\u003eYokogawa ANB10D-410\/NDEL\u003c\/strong\u003e (\u003cstrong\u003eANB10D\u003c\/strong\u003e Node Unit) provides direct physical\/electrical execution of dual-redundant ESB bus communication and backplane power distribution for modular FIO systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode \/ Option\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eANB10D\u003c\/td\u003e\n\u003ctd\u003eBase Node Unit for ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-4\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e24 V DC power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/NDEL\u003c\/td\u003e\n\u003ctd\u003eSoftware License for Node Expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANB10D-410\/NDEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e53 mm × 110 mm × 170 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 16 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Instrumentation Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e The unit supports transparent communication for HART-enabled field devices, allowing for remote diagnostic data collection and parameter configuration directly through the DCS environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e The architecture allows for modular integration of digital fieldbus networks, ensuring compatibility with standardized process automation protocols.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e Each I\/O channel path is isolated to prevent common-mode noise propagation and ground loop currents between field devices and the DCS backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e Internal high-precision sensing circuits provide active CJC for thermocouple inputs, ensuring accurate temperature measurement across varying ambient conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ANB10D-410\/NDEL support hot-swapping of I\/O modules?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The node unit is designed to support the hot-swapping of connected I\/O modules without interrupting the primary ESB bus communication or power delivery to other functional modules.\u003c\/p\u003e\n\u003cp\u003eQ: What is the purpose of the \/NDEL software license?\u003c\/p\u003e\n\u003cp\u003eA: The \/NDEL option provides the necessary software authorization for node expansion. This is mandatory for systems configured to scale beyond the initial node capacity within the DCS logic architecture.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the node unit in a cabinet with adequate ventilation. Adherence to the specified -20 deg C to +60 deg C operating temperature range is mandatory to prevent thermal degradation of the internal power regulation components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Bond the module chassis to the cabinet’s dedicated instrument earth bus using a low-impedance conductor. Proper shielding of the ESB bus cables is mandatory to mitigate EMI and ensure stable data transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminate 24 V DC power inputs using appropriately rated cabling to handle current demand. Ensure digital and analog signal wires are segregated from high-power conduits to maintain signal integrity and prevent induced noise.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48125156360382,"sku":"ANB10D-410\/NDEL","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-10_10-11-23.png?v=1783661726","url":"https:\/\/www.autooiltech.com\/products\/yokogawa-anb10d-410-ndel-node-unit","provider":"AutoOilTech Limited","version":"1.0","type":"link"}