{"product_id":"yokogawa-afv10d-s4115-duplexed-field-control","title":"Yokogawa AFV10D-S4115 Duplexed Field Control","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa AFV10D-S41151\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAFV10D\u003c\/strong\u003e Duplexed Field Control Unit, operates as a dedicated hardware component for high-availability process control and Vnet\/IP communication within CENTUM VP system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAFV10D-S41151\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e221 mm (H) x 482.6 mm (W) x 440 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eSystem specifications dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e200 VA (100-120 V AC) \/ 230 VA (220-240 V AC) \/ 5.5 A (24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDuplexed CP451 processors \/ Dual-redundant power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e The unit manages FIO communication, supporting pass-through of HART protocol data from field instrumentation to the control function for asset management and process monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e Integration with the field control station allows for high-speed deterministic data exchange, supporting standardized digital bus communications within the CENTUM VP architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e The modular design ensures electrical isolation between internal processing boards and field I\/O segments, maintaining signal integrity and protection against common-mode noise across the I\/O bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e The unit interfaces with associated FIO modules that provide precise thermal compensation for thermocouple-based temperature measurement inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the dual-redundant power modules be replaced under load?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The power modules (PW481\/PW482\/PW484) are hot-swappable. The unit may remain operational while one module is removed, provided the remaining module maintains sufficient power capacity for the rack configuration.\u003c\/p\u003e\n\u003cp\u003eQ: How does the duplexed processor configuration affect failover time?\u003c\/p\u003e\n\u003cp\u003eA: The standby CP451 processor maintains real-time memory synchronization with the active module. In the event of a fault, control execution transfers to the standby module within milliseconds, maintaining process output states without requiring a system reset.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the AFV10D chassis into a standard 19-inch industrial rack using the 5U height profile requirements. Ensure the chassis is mechanically bonded to the rack frame to maintain structural integrity under vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the chassis ground terminal to the site protective earth (PE) bus using a low-impedance conductor. Proper grounding is mandatory to prevent electromagnetic interference (EMI) on the dual-redundant Vnet\/IP ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Maintain strict segregation between high-voltage power input lines and the FIO bus communication cables. Use appropriate strain relief for all field cables to protect the internal backplane connectors from mechanical stress.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48157571612862,"sku":"AFV10D-S4115","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-09_16-36-30_386a4ebc-a1e9-49ef-8290-1c31ed10a304.png?v=1783936739","url":"https:\/\/www.autooiltech.com\/products\/yokogawa-afv10d-s4115-duplexed-field-control","provider":"AutoOilTech Limited","version":"1.0","type":"link"}