{"product_id":"yokogawa-adv551-p50-d5a00-digital-output-modules","title":"Yokogawa ADV551-P50\/D5A00 Digital Output Modules","description":"\u003cp\u003eConfigured for high-density digital signal execution in distributed control networks, the \u003cstrong\u003eYokogawa ADV551-P50\/D5A00\u003c\/strong\u003e (\u003cstrong\u003eADV551\u003c\/strong\u003e Digital Output Modules) provides direct physical and electrical actuation across field process loops.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel \/ Suffix Code Element\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDesignation \u0026amp; Specification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV551\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-P\u003c\/td\u003e\n\u003ctd\u003eWith pulse width output function \/ time-proportional output function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eWithout status display; with no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/D5A00\u003c\/td\u003e\n\u003ctd\u003eWith KS Cable Interface Adapter for 32-channel digital [Model: ATD5A-00]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV551-P50\/D5A00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan \/ Authorized Manufacturing Facility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 Kg (Shipping weight: 1.5 Kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Yokogawa Modular Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial rack rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard internal backplane current draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd\u003e32 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC, 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply Voltage Range\u003c\/td\u003e\n\u003ctd\u003e20.4 to 26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Format\u003c\/td\u003e\n\u003ctd\u003eCurrent sink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Instrumentation and Channel Isolation Architecture\u003c\/h3\u003e\n\u003cp\u003eThe hardware implements stringent channel-to-system electrical isolation with a withstanding voltage rating of 2 kV AC for 1 minute between output signals and internal system logic. Furthermore, galvanic boundaries are enforced across common minus side groupings every 16 channels, sustaining a withstanding voltage of 500 V AC for 1 minute.\u003c\/p\u003e\n\u003cp\u003eSignal conditioning circuitry supports robust common-mode noise suppression, maintaining accurate current sink actuation across distributed process control loops and interface adapters.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the response time parameters for status and pulse outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The output response time is 3 ms or less for status output, and 10 ms or less for mixed status and pulse outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What pulse width configuration limits apply to this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module supports pulse widths ranging from 8 ms to 7200 s with an 8 ms resolution, adding an ON\/OFF delay of maximum 1 ms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the \/D5A00 option modify field connectivity?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \/D5A00 option code integrates a KS Cable Interface Adapter specifically designed for 32-channel digital connections [Model: ATD5A-00].\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the module firmly into the designated modular rack slot to guarantee proper backplane bus pin engagement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Separation:\u003c\/strong\u003e Route digital output signal lines away from sensitive analog and power conduits to prevent electromagnetic interference coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Connect all cable shield drains to the designated grounding bar inside the termination cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e Inspect terminal connections and verify power supply voltage ranges prior to system energization.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48231290765502,"sku":"ADV551-P50\/D5A00","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-11_15-24-55_ccc6add8-e32d-4035-9db7-f9f3b3169d96.png?v=1785396039","url":"https:\/\/www.autooiltech.com\/products\/yokogawa-adv551-p50-d5a00-digital-output-modules","provider":"AutoOilTech Limited","version":"1.0","type":"link"}