{"product_id":"yokogawa-adm52c-ce1-s2-centum-output-modules","title":"Yokogawa ADM52C\/CE1 S2 CENTUM Output Modules","description":"\u003cp\u003eConfigured for digital signal conversion and relay output command execution in CENTUM series DCS networks, the \u003cstrong\u003eYokogawa ADM52C\/CE1 S2\u003c\/strong\u003e (\u003cstrong\u003eADM52C\/CE1 S2\u003c\/strong\u003e Digital Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Suffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCore Function Architecture\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eArchitectural Application\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADM52C\/CE1 S2\u003c\/td\u003e\n\u003ctd\u003eStandard Transistor Digital Output Module\u003c\/td\u003e\n\u003ctd\u003eYokogawa CENTUM DCS I\/O Racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eADM52C...\u003c\/td\u003e\n\u003ctd\u003eBase Variant Family\u003c\/td\u003e\n\u003ctd\u003eDistributed Control System Switching Interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADM52C\/CE1 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg (0.31 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130.0 mm x 25.0 mm x 110.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3.5 W nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e16 or 32 contact output points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eTransistor contact output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e12 to 32 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Range\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and 4-20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003eThe ADM52C\/CE1 S2 module incorporates channel-to-channel isolation architecture to eliminate ground loops and prevent electrical noise propagation between external field actuators and internal CENTUM processor nodes. It processes fast-response transistor switching commands across redundant bus pathways, ensuring deterministic actuation of on\/off control loops. Furthermore, internal signal conditioning circuitry maintains strict voltage tolerance limits across 12 to 32 V DC supply rails, protecting downstream switching elements from transient inductive kickback during rapid solenoid de-energization.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum switching voltage supported by the transistor contact outputs of this module?\u003c\/p\u003e\n\u003cp\u003eA: The module supports an output voltage range from 12 to 32 V DC for driving external industrial control devices.\u003c\/p\u003e\n\u003cp\u003eQ: Can the ADM52C\/CE1 S2 module be inserted or removed under live system power?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swap capabilities depend on the specific node chassis design; however, standard DCS maintenance protocols recommend isolating node power to prevent backplane bus disruption.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that the node baseplate is completely de-energized before mounting the ADM52C\/CE1 S2 module into the designated CENTUM DCS rack slot. Route external actuator control wiring through dedicated cable ducts, maintaining physical separation from high-voltage power lines to prevent electromagnetic coupling. Verify that terminal block connections are torqued securely and that module retaining screws are fully tightened to maintain reliable backplane edge-connector engagement.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48221131964606,"sku":"ADM52C\/CE1 S2","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/ADM12CS2_2___1.png?v=1785291240","url":"https:\/\/www.autooiltech.com\/products\/yokogawa-adm52c-ce1-s2-centum-output-modules","provider":"AutoOilTech Limited","version":"1.0","type":"link"}