{"product_id":"yokogawa-adm12t-contact-input-module","title":"Yokogawa ADM12T Contact Input Module","description":"\u003ch3\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eYokogawa ADM12T\u003c\/strong\u003e is a Contact Input Module designed for distributed control systems, supporting 32 input points with reliable ON\/OFF detection, push‑button input capability, and edge counting functions. It ensures stable signal acquisition with common minus side insulation and robust installation features.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003eHardware \u003c\/span\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e ADM12T\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Yokogawa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Contact Input Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNo. of I\/O Points:\u003c\/strong\u003e 32 points\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContact input: OFF ≥100 kΩ, ON ≤200 Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVoltage input: OFF 4.5–25 V DC, ON ±1 V DC, ≤200 Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eContact Rating:\u003c\/strong\u003e 5 V DC, ≥20 mA (external contact standard)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePulse Width:\u003c\/strong\u003e ≥40 ms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePulse Period:\u003c\/strong\u003e ≤10 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e ≤600 mA (5.0 V DC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunctions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStatus input\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePush‑button input\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eON\/OFF status detection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEdge counting for push‑buttons\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSignal Insulation:\u003c\/strong\u003e Common minus side\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting Method:\u003c\/strong\u003e Installed in the I\/O module nest\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSignal Connection:\u003c\/strong\u003e Terminal connection with M4 screws\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003eKey \u003c\/span\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e32 input points\u003c\/strong\u003e for flexible signal acquisition.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePush‑button input\u003c\/strong\u003e capability with edge detection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eON\/OFF detection\u003c\/strong\u003e ensures accurate monitoring of contact signals.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePulse handling\u003c\/strong\u003e with minimum 40 ms width and ≤10 Hz period.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommon minus side insulation\u003c\/strong\u003e for reliable system integration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003eFrequently \u003c\/span\u003e\u003cspan\u003eAsked \u003c\/span\u003e\u003cspan\u003eQuestions \u003c\/span\u003e\u003cspan\u003e(FAQ)\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eQ: How many signals can the ADM12T handle? A: It supports 32 contact input points.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: Can the module detect push‑button edges? A: Yes, it includes a function to count push‑button edges.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: What is the minimum pulse width supported? A: The module requires a minimum pulse width of 40 ms.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003eField \u003c\/span\u003e\u003cspan\u003eInstallation \u003c\/span\u003e\u003cspan\u003eGuidelines\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstall the ADM12T securely into the I\/O module nest.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConnect signals to the nest terminal using M4 screws with proper torque.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaintain shield grounding at a single point to prevent ground loops.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeparate signal wiring from high‑voltage cabling to minimize interference.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConfigure input signal ranges via system software before commissioning.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":47605148123326,"sku":"ADM12T","price":1500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/ADM11_3.jpg?v=1780467304","url":"https:\/\/www.autooiltech.com\/products\/yokogawa-adm12t-contact-input-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}