{"product_id":"ut-output-pack-副本","title":"GE 342A4903ADP218 Control Module","description":"\u003cp\u003eConfigured for module interfacing and turbine monitoring within GE Fanuc PLC and GE Speedtronic Mark II turbine controller networks, the \u003cstrong\u003eGE 342A4903ADP218\u003c\/strong\u003e (\u003cstrong\u003e342A4903ADP218\u003c\/strong\u003e Control Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Suffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCore Function Architecture\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eArchitectural Application\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e342A4903ADP218\u003c\/td\u003e\n\u003ctd\u003eStandard Control and Automation Module\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc PLC and Speedtronic Mark II Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e342A4903ADP...\u003c\/td\u003e\n\u003ctd\u003eBase Variant Family\u003c\/td\u003e\n\u003ctd\u003eIndustrial Turbine and Process Control Platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e342A4903ADP218\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e220.0 mm x 40.0 mm x 180.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10.0 W nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eControl \/ Automation Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Protection\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Chassis Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eProprietary Backplane Bus Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 342A4903ADP218 module utilizes robust backplane bus communication velocity architecture to interface reliably with legacy Speedtronic Mark II control racks and GE Fanuc PLC backplanes. It processes discrete and analog signal inputs deterministically, maintaining strict update rates under high electrical noise conditions. Furthermore, internal firmware flash compatibility allows secure binary management and parameter configuration adjustments through authorized engineering tools without requiring hardware replacement.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the primary control platforms supported by the 342A4903ADP218 module?\u003c\/p\u003e\n\u003cp\u003eA: The module is engineered specifically for integration within GE Fanuc PLC systems and GE Speedtronic Mark II turbine control frameworks.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support hot-swap replacement during active industrial plant operation?\u003c\/p\u003e\n\u003cp\u003eA: Maintenance personnel must isolate system power prior to insertion or removal to prevent electrical arcing and backplane connector damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that all rack power supplies are completely de-energized and locked out before handling the 342A4903ADP218 module. Guide the circuit board smoothly along the internal chassis card rails to prevent bending pins on the backplane connector. Fasten all front-panel securing screws evenly to ensure proper mechanical retention and reliable chassis grounding for electromagnetic shielding.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48221133930686,"sku":"342A4903ADP218","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-07_17-37-14_48f7da46-3eea-43ef-bf64-f36d0523eac7.png?v=1785288286","url":"https:\/\/www.autooiltech.com\/products\/ut-output-pack-%e5%89%af%e6%9c%ac","provider":"AutoOilTech Limited","version":"1.0","type":"link"}