{"product_id":"schneider-modicon-x80-bmxcps3020-power-supply-module","title":"Schneider Modicon X80 | BMXCPS3020 | Power Supply Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eBMXCPS3020\u003c\/strong\u003e from Schneider Electric’s Modicon X80 series is a high-performance DC power supply module designed for automation systems requiring stable and reliable operation. With wide input voltage support and multiple protection features, it ensures safe and efficient performance in industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMain Features:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e Modicon X80\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType:\u003c\/strong\u003e Power Supply Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Not compatible with BMEXBP..02 backplane\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePrimary Voltage:\u003c\/strong\u003e 24…48 V DC isolated\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCircuit Type:\u003c\/strong\u003e DC supply\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput Performance:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e3.3 V DC logic supply:\u003c\/strong\u003e 15 W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e24 V DC I\/O and processor supply:\u003c\/strong\u003e 31.2 W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaximum power dissipation:\u003c\/strong\u003e 8.5 W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput current:\u003c\/strong\u003e 1.3 A (24 V DC), 4.5 A (3.3 V DC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Performance:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVoltage range:\u003c\/strong\u003e 18…62.4 V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput current:\u003c\/strong\u003e 0.83 A at 48 V, 1.65 A at 24 V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInrush current:\u003c\/strong\u003e 30 A (24 V), 60 A (48 V)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eI²t value:\u003c\/strong\u003e 1 A²·s (24 V), 3 A²·s (48 V)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIt value:\u003c\/strong\u003e 0.2 A·s (24 V), 0.3 A·s (48 V)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection Functions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInternal fuse:\u003c\/strong\u003e Non-accessible for primary circuit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOverload protection:\u003c\/strong\u003e 24 V sensor supply\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOvervoltage protection:\u003c\/strong\u003e 24 V sensor supply\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShort-circuit protection:\u003c\/strong\u003e 24 V sensor supply\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReliability and Indicators:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMTBF:\u003c\/strong\u003e 4,600,000 hours\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStatus LED:\u003c\/strong\u003e Green (rack voltage OK)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eControl:\u003c\/strong\u003e Reset push-button for cold restart\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAlarm relay connector:\u003c\/strong\u003e 2-pin\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLine supply connector:\u003c\/strong\u003e 5-pin (line supply, protective earth)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCable length:\u003c\/strong\u003e Up to 10 m (1.5 mm² copper), 15 m (2.5 mm² copper)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e ≥ 10 MΩ (primary\/ground, primary\/secondary)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNet weight:\u003c\/strong\u003e 0.34 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Characteristics:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMicrobreak immunity:\u003c\/strong\u003e 1 ms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDielectric strength:\u003c\/strong\u003e 1500 V (primary\/ground, primary\/secondary)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVibration resistance:\u003c\/strong\u003e 3 gn\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShock resistance:\u003c\/strong\u003e 30 gn\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection rating:\u003c\/strong\u003e IP20\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e -40…85 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e 0…60 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5…95 % at 55 °C (non-condensing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAltitude:\u003c\/strong\u003e 0…2000 m; up to 5000 m with derating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompliance:\u003c\/strong\u003e 2014\/35\/EU Low Voltage Directive, 2014\/30\/EU EMC Directive\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe BMXCPS3020 is suitable for Modicon X80 automation platforms in manufacturing, energy, and process industries. Its wide input voltage range and robust protection functions make it ideal for critical control systems requiring stable DC power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can BMXCPS3020 operate with both 24 V and 48 V DC inputs?\u003c\/strong\u003e A: Yes, it supports a wide input voltage range from 18 to 62.4 V.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the MTBF rating of this module?\u003c\/strong\u003e A: MTBF is 4,600,000 hours, ensuring long-term reliability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does it include overload and short-circuit protection?\u003c\/strong\u003e A: Yes, multiple protection mechanisms are integrated for safe operation.\u003c\/span\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46451140493502,"sku":"BMXCPS3020","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/schneider-electric-bmxcps3500-power-supply-module-2o2qjrqpjac.png?v=1772509060","url":"https:\/\/www.autooiltech.com\/products\/schneider-modicon-x80-bmxcps3020-power-supply-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}