{"product_id":"schneider-modicon-tsx-micro-tsxdsz08r5-digital-output-modules","title":"Schneider Electric TSXDSZ08R5 Modicon TSX Micro Digital Relay Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Schneider Electric TSXDSZ08R5 is a high-reliability relay output module designed for use within the Modicon TSX Micro programmable controller architecture. This unit provides eight independent, galvanically isolated relay contacts, facilitating the control of diverse field devices across varying voltage levels. By utilizing electromechanical relay switching, the module enables seamless integration between low-voltage PLC logic and higher-voltage AC or DC field loads, making it an essential component for industrial automation, process control, and machinery management.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEight (8) independent, normally open (NO) mechanical relay outputs.\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between field circuits and the internal controller backplane.\u003c\/li\u003e\n\u003cli\u003eIntegrated RC suppression networks to mitigate inductive spikes during load switching.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED indicators for real-time verification of individual relay states.\u003c\/li\u003e\n\u003cli\u003eRemovable screw terminal blocks for simplified field wiring and rapid maintenance.\u003c\/li\u003e\n\u003cli\u003eDesigned for robust performance in demanding industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe TSXDSZ08R5 is widely utilized in industrial environments requiring flexible, isolated switching, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThermal power plant boiler controls.\u003c\/li\u003e\n\u003cli\u003eFluid management and pumping stations.\u003c\/li\u003e\n\u003cli\u003eAutomated manufacturing and mineral extraction machinery.\u003c\/li\u003e\n\u003cli\u003eInterface applications where logic-level signals must drive high-voltage actuators or contactors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXDSZ08R5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e8 Normally Open (NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24-240 VAC \/ 24-48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current per Channel\u003c\/td\u003e\n\u003ctd\u003e2.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Module Current\u003c\/td\u003e\n\u003ctd\u003e10.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Switching Current\u003c\/td\u003e\n\u003ctd\u003e1 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Power Consumption\u003c\/td\u003e\n\u003ctd\u003e45 mA (5 VDC) \/ 60 mA (24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Voltage\u003c\/td\u003e\n\u003ctd\u003e2000 VAC (Contacts to Bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e10% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the system power is completely disconnected before installing or removing the module from the TSX Micro rack.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is firmly seated and locked into the chassis connector to ensure proper backplane communication.\u003c\/li\u003e\n\u003cli\u003eMaintain proper spacing for ventilation to ensure the module operates within its specified temperature range.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for field wiring where necessary to minimize electromagnetic interference (EMI) in high-noise environments.\u003c\/li\u003e\n\u003cli\u003eEnsure that total current draw across all channels does not exceed the module's 10 A limit to prevent thermal damage.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD precautions to prevent damage to internal PCB components.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":48845895270590,"sku":"TSXDSZ08R5","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/wm_1_c64248a4-9e80-4d2d-9599-9818910a1362.jpg?v=1788664450","url":"https:\/\/www.autooiltech.com\/products\/schneider-modicon-tsx-micro-tsxdsz08r5-digital-output-modules","provider":"AutoOilTech Limited","version":"1.0","type":"link"}