{"product_id":"schneider-electric-bmxsdo0802-modicon-x80-output-module","title":"Schneider Electric BMXSDO0802 Modicon X80 Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric BMXSDO0802\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eBMXSDO0802\u003c\/strong\u003e Discrete Output Module, operates as a dedicated hardware component for solid-state binary load switching within Modicon X80 control architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXSDO0802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States (US)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg (0.26 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Modicon X80 single-slot module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C evaluation baseline (-13 to 158 deg F environment range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSourced via local backplane connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Quantity\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Logic\u003c\/td\u003e\n\u003ctd\u003ePositive (Source configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e1.2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent per Channel\u003c\/td\u003e\n\u003ctd\u003e0.625 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per Module\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10 MOhm at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1500 V AC at 50\/60 Hz for 1 minute (output\/ground and output\/logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eConformal coating (Gas class 3C4\/Gx, Dust\/Sand class 3S4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF Reliability\u003c\/td\u003e\n\u003ctd\u003e383,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModicon X80 Platform Backplane Architecture\u003c\/h3\u003e\n\u003cp\u003eThe BMXSDO0802 hardware topology decodes parallel binary output command arrays designed to track system variables across backplane bus communication velocity Licences. By utilizing low-latency solid-state switching components operating on a 1.2 ms response timeline, the module drives inductive and ohmic load networks without introducing data conversion loop lag.\u003c\/p\u003e\n\u003cp\u003eThe internal physical layers manage synchronous bit states over Profinet \/ EtherNet\/IP deterministic networks via the master X80 backplane interface to maintain continuous connection tracking across the central processing unit. The specialized output configuration supports scalable I\/O density scaling routines by allowing the paralleling of up to 2 discrete outputs per electrical channel cluster to handle higher inductive currents. This processing core executes continuous preactuator fault diagnostics, cross-referencing real-time threshold voltage vectors (\u0026lt;14 V DC sensor fault and \u0026gt;18 V DC sensor OK states) while maintaining full software configuration firmware flash compatibility across standard EcoStruxure Control Expert engineering platforms.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the integrated short-circuit and overload protection respond during a continuous field fault?\u003c\/p\u003e\n\u003cp\u003eA: The module contains internal electronic trip barriers that automatically clamp current flow when a short-circuit or overload condition is detected on an active channel. The hardware registers a diagnostic fault bit, transitions the affected channel into a safe state, and updates the process image to notify the host processor.\u003c\/p\u003e\n\u003cp\u003eQ: What are the absolute grounding requirements to maintain the 1500 V AC dielectric isolation rating?\u003c\/p\u003e\n\u003cp\u003eA: The module requires a direct mechanical connection to the Modicon X80 backplane grounding structure. External field power commons and cable shields must terminate at a single low-impedance earth point within the enclosure to prevent transient voltage spikes from breaking down the internal logic isolation barriers.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47604626751678,"sku":"BMXSDO0802","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-05_09-16-39_00c01340-3c02-4d24-a093-a50c1c9803db.png?v=1780626050","url":"https:\/\/www.autooiltech.com\/products\/schneider-electric-bmxsdo0802-modicon-x80-output-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}