{"product_id":"schneider-electric-bmxamo0410-analog-output-module","title":"Schneider Electric BMXAMO0410 Analog Output Module","description":"\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBMXAMO0410\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eanalog output module is a high-precision 4-channel output module designed for the Schneider Electric Modicon X80 automation platform. It provides isolated current and voltage outputs suitable for process control, motion control, and industrial signal transmission applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModicon X80\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBMXAMO0410\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Output Module\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 isolated channels\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20-way single connector\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective Treatment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard version\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.15 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Output Types:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003eCurrent: 0–20 mA\u003c\/li\u003e\n\u003cli\u003eCurrent: 4–20 mA\u003c\/li\u003e\n\u003cli\u003eVoltage: ±10 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e15 bits + sign\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Output Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e0–21 mA (for 0–20 mA mode)\u003c\/li\u003e\n\u003cli\u003e0–21 mA (for 4–20 mA mode)\u003c\/li\u003e\n\u003cli\u003e±10.5 V (for ±10 V mode)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLoad Impedance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e≥ 1000 Ω (±10 V)\u003c\/li\u003e\n\u003cli\u003e≤ 500 Ω (0–20 mA)\u003c\/li\u003e\n\u003cli\u003e≤ 500 Ω (4–20 mA)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConversion Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e≤ 1 ms\u003cbr\u003e\u003cstrong\u003eOutput Level:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh level\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy and Performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Error:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e≤ 0.2 % of full scale (0–60 °C)\u003c\/li\u003e\n\u003cli\u003e0.1 % of full scale at 25 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Drift:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e45 ppm\/°C (±10 V)\u003c\/li\u003e\n\u003cli\u003e45 ppm\/°C (0–20 mA)\u003c\/li\u003e\n\u003cli\u003e45 ppm\/°C (4–20 mA)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Crosstalk Attenuation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e80 dB\u003cbr\u003e\u003cstrong\u003eCommon Mode Rejection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 dB\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMTBF:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1,000,000 hours\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation and Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e1400 V DC between channels and ground\u003c\/li\u003e\n\u003cli\u003e1400 V DC between channels and bus\u003c\/li\u003e\n\u003cli\u003e750 V DC between channels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFault Detection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003eOpen circuit detection (0–20 mA)\u003c\/li\u003e\n\u003cli\u003eOpen circuit detection (4–20 mA)\u003c\/li\u003e\n\u003cli\u003eShort circuit detection (±10 V)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFallback Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003eConfigurable\u003c\/li\u003e\n\u003cli\u003ePredefined safe value option\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInternal via X80 rack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e3 W typical at 24 V DC\u003c\/li\u003e\n\u003cli\u003e3.6 W maximum at 24 V DC\u003c\/li\u003e\n\u003cli\u003e0.45 W typical at 3.3 V DC\u003c\/li\u003e\n\u003cli\u003e0.51 W maximum at 3.3 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e150 mA at 3.3 V DC\u003c\/li\u003e\n\u003cli\u003e140 mA at 24 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 °C to 60 °C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e–40 °C to 85 °C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5 % to 95 % at 55 °C non-condensing\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Altitude:\u003c\/strong\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e0 to 2000 m\u003c\/li\u003e\n\u003cli\u003e2000 to 5000 m with derating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3 gn\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e30 gn\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAre the output channels electrically isolated?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, each channel is isolated from ground, bus, and other channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDoes the module detect output wiring faults?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, it supports open-circuit detection for current outputs and short-circuit detection for voltage outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan fallback values be configured?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, predefined or user-configurable fallback modes are available for safe operation.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46427841429694,"sku":"BMXAMO0410","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/schneider-electric-bmxddo3202k-discrete-output-module-k25fqkrp0pj.png?v=1772094676","url":"https:\/\/www.autooiltech.com\/products\/schneider-electric-bmxamo0410-analog-output-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}