{"product_id":"schneider-electric-bmexbp0400-ethernet-backplane","title":"Schneider Electric BMEXBP0400 Ethernet Backplane","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe\u003cstrong\u003e BMEXBP0400\u003c\/strong\u003e Modicon X80 4-Slot Rack is part of the Modicon X80 automation platform from Schneider Electric, designed to host I\/O modules, processors, and power supplies in industrial control systems. With integrated bus X + Ethernet connectivity, high reliability, and flexible mounting options, this rack provides the backbone for scalable automation architectures.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003ch4\u003eMain Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRange of Product:\u003c\/strong\u003e Modicon X80\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAccessory Type:\u003c\/strong\u003e Rack\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Slots:\u003c\/strong\u003e 4 (bus X + Ethernet)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Compatibility:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eI\/O modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBMX processors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBMXCPS power supply\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBME processors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectrical Characteristics\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e162 mW at 3.3 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e2.8 W at 24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e49 mA at 3.3 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e118 mA at 24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Connection:\u003c\/strong\u003e 1 connector (XBE expansion module)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical \u0026amp; Mounting\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFixing Modes:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e4 screws (Ø 4.32–6.35 mm), panel mounting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e4 M6 screws, plate mounting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eClips, 35 mm symmetrical DIN rail mounting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.705 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMTBF Reliability:\u003c\/strong\u003e 1,588,025 hours\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironmental Ratings\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIP Protection:\u003c\/strong\u003e IP20\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0–60 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5–95% (non-condensing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDirectives Compliance:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e2014\/35\/EU (Low Voltage Directive)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e2014\/30\/EU (Electromagnetic Compatibility Directive)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFunctional Role\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvides structural and electrical support for Modicon X80 modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsures reliable communication via bus X and Ethernet backplane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOffers flexible installation options for panel, plate, or DIN rail mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for long service life with high MTBF reliability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial automation systems\u003c\/strong\u003e requiring modular expansion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProcess control environments\u003c\/strong\u003e with Ethernet and bus X communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturing plants\u003c\/strong\u003e needing scalable I\/O integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnergy and utilities\u003c\/strong\u003e where reliability and compliance are critical\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many slots does the rack provide?\u003c\/strong\u003e A: It offers 4 slots with bus X and Ethernet connectivity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What modules are compatible?\u003c\/strong\u003e A: BMX processors, BMXCPS power supplies, BME processors, and I\/O modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can it be mounted on a DIN rail?\u003c\/strong\u003e A: Yes, it supports DIN rail, panel, and plate mounting.\u003c\/span\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46377625977022,"sku":"BMEXBP0400","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/schneider-electric-bmexbp1200-rack-rfg35oe2235.png?v=1773726032","url":"https:\/\/www.autooiltech.com\/products\/schneider-electric-bmexbp0400-ethernet-backplane","provider":"AutoOilTech Limited","version":"1.0","type":"link"}