{"product_id":"schneider-bmxsd00802-safety-discrete-output-module","title":"Schneider BMXSD00802 Safety Discrete Output Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eBMXSDO0802\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability discrete safety output module within the Schneider Electric Modicon X80 series. Engineered for SIL3 safety architectures, this module provides 8 solid-state, positive logic (source) outputs at a nominal 24 V DC. It is designed to drive critical safety actuators such as contactors, solenoids, and signal lamps in high-stakes environments including energy production, heavy manufacturing, and large-scale infrastructure. Featuring real-time diagnostics and an integrated electronic circuit breaker, the\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eBMXSDO0802\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eensures that safety-critical loops remain functional and protected against field-side electrical faults.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSchneider Electric\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eModel Number:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eBMXSDO0802\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeries:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eModicon X80 Safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOutput Channels:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e8 Discrete Outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOutput Type:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSolid-state, Positive Logic (Source)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNominal Voltage:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e24 V DC (Range: 19–30 V DC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCurrent per Channel:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e0.625 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaximum Module Current:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e10 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResponse Time:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e1.2 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSafety Integrity Level:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSIL3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReliability (MTBF):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e383,000 Hours\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePower Dissipation:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e4.4 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLeakage Current:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e0.5 mA (at State 0)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVoltage Drop:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u0026lt; 1.2 V (at State 1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSwitching Frequency:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e0.5 \/\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord mathnormal\"\u003eL\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eI\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e2\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInsulation Resistance:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt; 10 MΩ @ 500 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCurrent Consumption:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e264 mA @ 3.3 V DC \/ 15 mA @ 24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConnector Requirement:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e20-point Terminal Block (e.g., BMXFTB2000)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvanced Safety \u0026amp; Protection Features\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eBMXSDO0802\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eis equipped with a multi-layered protection strategy to maintain the integrity of the safety loop:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverload Management:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes both a hardware current limiter and an intelligent electronic circuit breaker.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOvervoltage Suppression:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated Transil diodes protect the internal circuitry from inductive kicks and surges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFault Diagnostics:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eReal-time monitoring of channel states with dedicated LEDs and a system-level ERR indicator for rapid troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRedundancy Support:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eAllows for the paralleling of up to two outputs to increase current capacity or provide hardware redundancy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46553977323710,"sku":"BMXSD00802","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/12.png?v=1775110472","url":"https:\/\/www.autooiltech.com\/products\/schneider-bmxsd00802-safety-discrete-output-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}