{"product_id":"schneider-140aco13000-analog-output-module","title":"Schneider 140ACO13000 Analog Output Module","description":"\u003cp\u003eConfigured for high-density analog signal generation and current loop regulation within Modicon Quantum automation architectures, the \u003cstrong\u003eSchneider Electric 140ACO13000\u003c\/strong\u003e (\u003cstrong\u003e140ACO13000\u003c\/strong\u003e Analog Output Module) provides direct physical\/electrical execution. It converts internal digital variables natively at the backplane tier into continuous analog control signals parallel to master control network platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e140ACO13000 (140-ACO-130-00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric (Modicon)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eQuantum Automation Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance \/ United States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.66 lbs (Approx. 0.30 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e6 to 30 VDC external loop potential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Channel Output\u003c\/td\u003e\n\u003ctd\u003e550 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Density\u003c\/td\u003e\n\u003ctd\u003e8 isolated Analog Output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eLED diagnostic indicator array\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued by manufacturer (Recommended replacement: BMXAMO0802)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Drive Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity Licences and Processing Logic:\u003c\/strong\u003e The module processes digital commands from the Modicon Quantum backplane over dedicated logic registers. Because digital-to-analog step parsing occurs within localized hardware chips, updating output variables does not restrict the backplane bus communication velocity properties assigned to critical safety interlocks or peer controller tasks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP Deterministic Networks Mapping:\u003c\/strong\u003e Active output register values and internal channel diagnostic faults are tracked inside a local data table. This configuration maps to supervisory Profinet \/ EtherNet\/IP deterministic networks via external network head adapters, keeping distributed SCADA platforms updated without communication delays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling and Output Control Configuration:\u003c\/strong\u003e Providing 8 high-current analog channels across a 0.66 lbs frame optimizes panel space. This distribution expands overall I\/O density scaling profiles inside centralized termination cabinets, allowing engineers to interface directly with dynamic valve actuators without needing auxiliary booster components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What technical tracking behavior manifests if the external 6-30 VDC loop power supply undergoes an electrical interruption?\u003c\/p\u003e\n\u003cp\u003eA: The module's internal voltage monitoring network drops its valid channel register bit instantly. The front faceplate turns on an external fault LED indicator, and a loop-power failure code is transmitted across the backplane bus to flag the diagnostic drop on the master processor.\u003c\/p\u003e\n\u003cp\u003eQ: Can this 0.66 lbs Modicon Quantum module be hot-swapped while the primary chassis backplane remains fully energized?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the Modicon Quantum chassis architecture features staggered backplane connector contacts that support live hot-swapping. The module can be extracted and inserted while power is live, provided the field terminal block is safely unlatched first to avoid transient voltage surges across active channels.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":47750523977918,"sku":"140ACO13000","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-25_15-37-09_eaf77118-634c-48d2-8e46-97150d5ad245.png?v=1782385477","url":"https:\/\/www.autooiltech.com\/products\/schneider-140aco13000-analog-output-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}