{"product_id":"is200tbtch1cbb-ge-thermocouple-input-terminal-board","title":"IS200TBTCH1CBB | GE | Thermocouple Input Terminal Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eConfigured for turbine‑temperature acquisition within the Mark VIe platform, the \u003cstrong\u003eGE IS200TBTCH1CBB\u003c\/strong\u003e, also cataloged as the\u003cstrong\u003e \u003c\/strong\u003eTBTCH1C thermocouple terminal board, provides 24‑channel thermocouple interfacing through barrier‑type terminal blocks and DC‑type backplane connectors. The board supports multiple thermocouple types and integrates cold‑junction reference devices for stable measurement accuracy.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe IS200TBTCH1CBB identifier does not define decomposable suffix elements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNo variant matrix is available in the provided documentation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe part number is treated as a fixed Mark VIe TBTC hardware designation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e IS200TBTCH1CBB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e GE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e Mark VIe\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Thermocouple Input Terminal Board\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eChannels:\u003c\/strong\u003e 24 thermocouple channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSupported Types:\u003c\/strong\u003e E, J, K, S, T\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSpan:\u003c\/strong\u003e -8 mV to +45 mV\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 to +45°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSize:\u003c\/strong\u003e 15.9 cm high × 17.8 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAvailability:\u003c\/strong\u003e In stock\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e United States\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManual Reference:\u003c\/strong\u003e GEH‑6421M\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThermocouple Signal Behavior \u0026amp; PTCC Pack Compatibility\u003c\/h3\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports grounded and ungrounded thermocouples up to 300 m from the turbine control panel.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum allowable two‑way cable resistance: 450 ohms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIncludes high‑frequency noise suppression and dual cold‑junction reference devices for stable measurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInterfaces with PTCC I\/O packs through DC‑type connectors:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTBTCH1C (Simplex):\u003c\/strong\u003e two DC connectors, supports two PTCC packs for full 24‑channel acquisition.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTBTCH1B (TMR):\u003c\/strong\u003e six DC connectors, supports one to three PTCC packs, providing 12‑channel capability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports simplex, dual, and TMR Mark VIe configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can the TBTCH1CBB support mixed thermocouple types simultaneously?\u003c\/strong\u003e \u003cstrong\u003eA:\u003c\/strong\u003e Yes. Each channel is independent and supports any of the listed thermocouple types.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does the board provide its own cold‑junction compensation?\u003c\/strong\u003e \u003cstrong\u003eA:\u003c\/strong\u003e Yes. Two onboard cold‑junction reference devices provide compensation for all channels.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Are long‑distance thermocouple runs supported?\u003c\/strong\u003e \u003cstrong\u003eA:\u003c\/strong\u003e Yes. Up to 300 meters, provided cable resistance does not exceed 450 ohms.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUse the two removable barrier‑type terminal blocks for thermocouple wiring; each block supports #12 AWG conductors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnsure shield terminals are bonded to chassis ground to minimize noise.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVerify DC‑type connector seating before powering the system.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRoute thermocouple wiring away from high‑voltage conductors to avoid induced noise.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConfirm PTCC pack quantity and connector alignment based on simplex or TMR configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInspect cold‑junction devices for proper placement and thermal contact.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45446751092926,"sku":"IS200TBTCH1CBB","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/general-electric-is200tambh1acb-acoustic-monitoring-terminal-board-ktgqektf2d1.png?v=1759132338","url":"https:\/\/www.autooiltech.com\/products\/is200tbtch1cbb-ge-thermocouple-input-terminal-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}