{"product_id":"is200jpdeg1a-ge-dc-battery-distribution-board","title":"IS200JPDEG1A | GE | DC Battery Distribution Board","description":"\u003ch2\u003eGE IS200JPDEG1A DC Battery Distribution Board\u003c\/h2\u003e\n\u003cp\u003eConfigured for DC battery‑sourced power routing in Mark VIe turbine control systems, the \u003cstrong\u003eGE IS200JPDEG1A\u003c\/strong\u003e (\u003cstrong\u003eIS200JPDEG1A\u003c\/strong\u003e DC Battery Distribution Board) provides fixed electrical distribution paths, diagnostic feedback routing, and battery‑input protection within PDM‑style assemblies.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe model string contains the following identifiable elements:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIS200\u003c\/strong\u003e — Mark VIe PCB family\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJPDE\u003c\/strong\u003e — DC Battery Distribution functional acronym\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eG1\u003c\/strong\u003e — Normal‑coated PCB grouping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e — Functional revision A applied to the parent IS200JPDEG1 board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNo additional suffix variants or sub‑models are defined for \u003cstrong\u003eIS200JPDEG1A\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eIS200JPDEG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eGE Energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified (follow Mark VIe cabinet limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eDC Battery Distribution Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Acronym\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eJPDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eDC Battery Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePCB Coating\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNormal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Revision\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDiagnostic Connectors\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eTwo 50‑pin connectors (P1, P2) for PPDA feedback routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePower Input\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eTwo 9‑pin Mate‑n‑Lock connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eProtection Hardware\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eDC circuit breaker, 30 A input filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eVoltage‑Limiting Components\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eResistors, transistors, diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eMaintenance Switches\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eCustomizable switches for service tasks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eMetal mounting bracket with grounding terminal; four factory‑drilled holes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity Licences\u003c\/h3\u003e\n\u003cp\u003eAs a GE industrial control module, the IS200JPDEG1A aligns with deterministic Mark VIe power‑distribution timing. The board’s P1\/P2 diagnostic connectors support feedback propagation to PPDA I\/O packs without violating cabinet‑level timing windows. Its normal‑coated hardware maintains compatibility with \u003cstrong\u003efirmware flash compatibility\u003c\/strong\u003e requirements for Mark VIe controllers. When integrated into turbine networks, the JPDE module supports deterministic behavior across \u003cstrong\u003eProfinet \/ EtherNet\/IP deterministic networks\u003c\/strong\u003e and aligns with cabinet‑level \u003cstrong\u003eI\/O density scaling\u003c\/strong\u003e for modular power‑distribution assemblies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the IS200JPDEG1A require calibration after installation?\u003c\/strong\u003e A: No calibration parameters are defined. The board operates as a fixed‑function DC distribution module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are the maintenance switches user‑configurable?\u003c\/strong\u003e A: Yes. The switches are intended for service tasks but must be set according to cabinet documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the normal PCB coating affect electrical performance?\u003c\/strong\u003e A: No. The coating provides basic environmental protection but does not alter distribution behavior.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the board on the designated metal bracket to ensure correct grounding and mechanical stability.\u003c\/li\u003e\n\u003cli\u003eVerify correct seating of P1 and P2 diagnostic connectors to maintain PPDA feedback integrity.\u003c\/li\u003e\n\u003cli\u003eRoute battery‑input wiring separately from high‑energy turbine conductors to reduce noise coupling.\u003c\/li\u003e\n\u003cli\u003eInspect the DC circuit breaker and 30 A input filter for correct rating before energizing the cabinet.\u003c\/li\u003e\n\u003cli\u003eEnsure all terminal screws are torqued properly to avoid intermittent distribution paths.\u003c\/li\u003e\n\u003cli\u003eAvoid contamination of surface‑mount components; debris can create leakage paths under load.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48144093380798,"sku":"IS200JPDEG1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-30_10-41-59_a868b064-a655-44a9-a5c8-2e7cc5c56d62.png?v=1782787591","url":"https:\/\/www.autooiltech.com\/products\/is200jpdeg1a-ge-dc-battery-distribution-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}