{"product_id":"is200aepah1bhc-is215wepah2ab-ge-printed-circuit","title":"IS200AEPAH1BHC (IS215WEPAH2AB) GE Printed Circuit","description":"\u003cp\u003eThe \u003cstrong\u003eGE IS200AEPAH1BHC\u003c\/strong\u003e (\u003cstrong\u003eIS215WEPAH2AB\u003c\/strong\u003e) Printed Circuit Board provides direct physical\/electrical execution for turbine control signal processing and data communication within industrial automation networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe complete module designation combines the primary assembly catalog number \u003cstrong\u003eIS200AEPAH1BHC\u003c\/strong\u003e with the factory hardware revision identifier \u003cstrong\u003eIS215WEPAH2AB\u003c\/strong\u003e, denoting the specific circuit layout and component population intended for GE turbine control systems. No arbitrary sub-modules exist for this printed circuit board assembly.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200AEPAH1BHC (IS215WEPAH2AB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard PCB format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard GE VME rack form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 differential or single-ended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 single-ended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003e200 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eCAN Bus (1 Mbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Rating\u003c\/td\u003e\n\u003ctd\u003e125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and Backplane Communication\u003c\/h3\u003e\n\u003cp\u003eThe printed circuit board handles high-speed data throughput via a deterministic internal architecture supporting configurable software frame rates of 10 ms, 20 ms, and 40 ms. The integrated CAN Bus communication interface maintains a strict 1 Mbps data transfer rate to ensure synchronous execution across distributed turbine control nodes. Signal acquisition paths utilize 16 differential or single-ended input channels paired with a 12-bit analog-to-digital converter operating at a 200 kHz sampling rate, preserving data fidelity and preventing latency across the backplane bus interface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the printed circuit board support hot-swappable installation within the rack?\u003c\/p\u003e\n\u003cp\u003eA: No, replacement requires completely de-energizing the corresponding rack chassis power supplies to prevent electrical arcing and backplane bus fault propagation.\u003c\/p\u003e\n\u003cp\u003eQ: How are firmware updates managed across the communication interface?\u003c\/p\u003e\n\u003cp\u003eA: Firmware configuration updates are executed through dedicated system software tools via the controller network backbone while the target processor slot is placed in a non-active state.\u003c\/p\u003e\n\u003cp\u003eQ: What is the primary function of the internal power conversion circuitry on this board?\u003c\/p\u003e\n\u003cp\u003eA: The board steps down and regulates incoming power distribution rails to supply a stable 5 VDC operating voltage directly to internal logic components and sampling circuits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInsert the printed circuit board carefully along the designated chassis guide slots, ensuring smooth mechanical engagement with the backplane connector before applying manual pressure. Fasten the top and bottom panel securing screws firmly to establish proper chassis ground continuity and prevent loosening from heavy industrial vibration. Route any external signal or communication wiring through separate metallic conduits away from high-voltage alternating current power feeds to maintain electromagnetic compatibility.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48231521550526,"sku":"IS200AEPAH1BHC (IS215WEPAH2AB)","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/DS200TCCAG1A_0b64e86e-e3ea-4bf6-8ff7-1b99415864b2.png?v=1785398925","url":"https:\/\/www.autooiltech.com\/products\/is200aepah1bhc-is215wepah2ab-ge-printed-circuit","provider":"AutoOilTech Limited","version":"1.0","type":"link"}